The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Consumer sleep tracking devices: a review of mechanisms, validity and utility
Abstract
Consumer sleep tracking devices such as fitness trackers and smartphone apps have become increasingly popular. These devices claim to measure the sleep duration of their users and in some cases purport to measure sleep quality and awaken users from light sleep, potentially improving overall sleep. Most of these devices appear to utilize data generated from in-built accelerometers to determine sleep parameters but the exact mechanisms and algorithms are proprietary. The growing literature comparing these devices against polysomnography/actigraphy shows that they tend to underestimate sleep disruptions and overestimate total sleep times and sleep efficiency in normal subjects. In this review, we evaluate the current literature comparing the accuracy of consumer sleep tracking devices against more conventional methods used to measure sleep duration and quality. We discuss the current technology that these devices utilize as well as summarize the value of these devices in clinical evaluations and their potential limitations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, the validity and utility of such devices for the diagnosis of insomnia has not been satisfactorily researched or demonstrated at this point in time (Kolla et al., 2016).”
From The European Insomnia Guideline: An update on the diagnosis and treatment of insomnia 2023 (2023) · cites this paper as Kolla et al., 2016
Citations
Cites
The role and validity of actigraphy in sleep medicine: an update
Sadeh, A. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2010.10.001 · Cited by 1,415
Morgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142
Psychophysiological insomnia: the behavioural model and a neurocognitive perspective
PERLIS, M. L., GILES, D. E., MENDELSON, W. B., BOOTZIN, R. R., & WYATT, J. K. (1997) · Journal of Sleep Research · doi:10.1046/j.1365-2869.1997.00045.x · Cited by 795
Watson, N. F., Badr, M. S., Belenky, G., Bliwise, D. L., Buxton, O. M., Buysse, D., Dinges, D. F., Gangwisch, J., Grandner, M. A., Kushida, C., et al. (2015) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.4950 · Cited by 568
Movement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301
Unobtrusive Sleep Monitoring using Smartphones
Chen, Z., Lin, M., Chen, F., Lane, N., Cardone, G., Wang, R., Li, T., Chen, Y., Choudhury, T., & Cambell, A. (2013) · Proceedings of the ICTs for improving Patients Rehabilitation Research Techniques · doi:10.4108/icst.pervasivehealth.2013.252148 · Cited by 300
Validation of an automated wireless system to monitor sleep in healthy adults
SHAMBROOM, J. R., FÁBREGAS, S. E., & JOHNSTONE, J. (2012) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2011.00944.x · Cited by 216
Evaluation of a consumer fitness-tracking device to assess sleep in adults
de Zambotti, M., Claudatos, S., Inkelis, S., Colrain, I. M., & Baker, F. C. (2015) · Chronobiology International · doi:10.3109/07420528.2015.1054395 · Cited by 127
Monitoring sleep with a smartphone accelerometer
NATALE, V., DREJAK, M., ERBACCI, A., TONETTI, L., FABBRI, M., & MARTONI, M. (2012) · Sleep and Biological Rhythms · doi:10.1111/j.1479-8425.2012.00575.x · Cited by 73
Research works printed but not linked: 26
- Watson NF, 2015, J Clin Sleep Med, 11, 931, 10.5664/jcsm.4926 · DOI
- Ando K, 2002, Isr J Psychiatry Relat Sci, 39, 11
- 10.1081/CBI-120019341 · DOI
- 10.1080/07420520500180439 · DOI
- 10.1097/00004850-200403000-00004 · DOI
- 10.1111/j.1365-2869.2008.00706.x · DOI
- 10.1016/0272-7358(95)00059-3 · DOI
- 10.1249/MSS.0b013e3182399f5e · DOI · Paper page
- Sadeh A, 1994, Sleep, 17, 201, 10.1093/sleep/17.3.201 · DOI · Paper page
- 10.1111/j.1365-2869.2010.00835.x · DOI
- 10.1145/2742647.2742674 · DOI · Paper page
- Nakano H, 2014, J Clin Sleep Med, 10, 73, 10.5664/jcsm.3364 · DOI
- Meltzer LJ, 2015, Sleep, 38, 1323, 10.5665/sleep.4918 · DOI · Paper page
- De Zambotti M, 2015, Sleep, 38, 1461, 10.5665/sleep.4990 · DOI · Paper page
- Toon E, J Clin Sleep Med
- 10.1371/journal.pone.0095824 · DOI
- 10.4103/1817-1737.105720 · DOI
- 10.1109/JBHI.2014.2307913 · DOI
- 10.1007/s11325-014-1009-6 · DOI
- 10.1017/S0022215115001978 · DOI
- 10.5664/jcsm.5288 · DOI · Paper page
- Zhenyu C, 2013, Pervasive computing technologies for healthcare (PervasiveHealth)
- Bhat S, 2015, J Clin Sleep Med, 11, 709, 10.5664/jcsm.4840 · DOI
- 10.1145/2556288.2557220 · DOI · Paper page
- 2014, International classification of sleep disorders – third edition (ICSD-3)
- 10.1088/0967-3334/34/7/R29 · DOI
Cited by
The European Insomnia Guideline: An update on the diagnosis and treatment of insomnia 2023
Riemann, D., Espie, C. A., Altena, E., Arnardottir, E. S., Baglioni, C., Bassetti, C. L. A., Bastien, C., Berzina, N., Bjorvatn, B., Dikeos, D., et al. (2023) · Journal of Sleep Research · doi:10.1111/jsr.14035 · Cited by 834
“According to two systematic reviews, many devices based on actigraphy underestimate the severity of sleep disorder symptoms and overestimate sleep duration compared with polysomnography (PSG; Kolla et al., 2016; Smith et al., 2018).”
BackgroundSleep and the athlete: narrative review and 2021 expert consensus recommendations
Walsh, N. P., Halson, S. L., Sargent, C., Roach, G. D., Nédélec, M., Gupta, L., Leeder, J., Fullagar, H. H., Coutts, A. J., Edwards, B. J., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-102025 · Cited by 571
Toward clinical digital phenotyping: a timely opportunity to consider purpose, quality, and safety
Huckvale, K., Venkatesh, S., & Christensen, H. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0166-1 · Cited by 433
Performance of seven consumer sleep-tracking devices compared with polysomnography
Chinoy, E. D., Cuellar, J. A., Huwa, K. E., Jameson, J. T., Watson, C. H., Bessman, S. C., Hirsch, D. A., Cooper, A. D., Drummond, S. P. A., & Markwald, R. R. (2021) · Sleep · doi:10.1093/sleep/zsaa291 · Cited by 433
A validation study of Fitbit Charge 2™ compared with polysomnography in adults
de Zambotti, M., Goldstone, A., Claudatos, S., Colrain, I. M., & Baker, F. C. (2018) · Chronobiology International · doi:10.1080/07420528.2017.1413578 · Cited by 413
Metadata
- Authors
- Kolla, B. P., Mansukhani, S., & Mansukhani, M. P.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2016-04-18
- Volume
- 13
- Issue
- 5
- Pages
- 497-506
- ISSN
- 1743-4440
- 1745-2422
- Cited by
- 144
- References
- 9
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Consumer sleep tracking devices: a review of mechanisms, validity and utility. https://app.cochat.ai/papers/10.1586/17434440.2016.1171708
- The paper
- Kolla, B. P., Mansukhani, S., & Mansukhani, M. P. (2016). Consumer sleep tracking devices: a review of mechanisms, validity and utility. Expert Review of Medical Devices. https://doi.org/10.1586/17434440.2016.1171708
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.