The DOI matches its Crossref record.
Mechanical, antibacterial and bond strength properties of nano-titanium-enriched glass ionomer cement
Open accessAbstract
The use of nanoparticles (NPs) has become a significant area of research in Dentistry. Objective The aim of this study was to investigate the physical, antibacterial activity and bond strength properties of conventional base, core build and restorative of glass ionomer cement (GIC) compared to GIC supplemented with titanium dioxide (TiO2) nanopowder at 3% and 5% (w/w). Material and Methods Vickers microhardness was estimated with diamond indenter. Compressive and flexural strengths were analyzed in a universal testing machine. Specimens were bonded to enamel and dentine, and tested for shear bond strength in a universal testing machine. Specimens were incubated with S. mutans suspension for evaluating antibacterial activity. Surface analysis of restorative conventional and modified GIC was performed with SEM and EDS. The analyses were carried out with Kolmogorov-Smirnov, ANOVA (post-hoc), Tukey test, Kruskal-Wallis, and Mann Whitney. Results Conventional GIC and GIC modified with TiO2 nanopowder for the base/liner cement and core build showed no differences for mechanical, antibacterial, and shear bond properties (p>0.05). In contrast, the supplementation of TiO2 NPs to restorative GIC significantly improved Vickers microhardness (p<0.05), flexural and compressive strength (p<0.05), and antibacterial activity (p<0.001), without interfering with adhesion to enamel and dentin. Conclusion GIC supplemented with TiO2 NPs (FX-II) is a promising material for restoration because of its potential antibacterial activity and durable restoration to withstand the mastication force.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical Applications of TiO2 Nanostructures: Recent Advances
Jafari, S., Mahyad, B., Hashemzadeh, H., Janfaza, S., Gholikhani, T., & Tayebi, L. (2020) · International Journal of Nanomedicine · doi:10.2147/ijn.s249441 · Cited by 505
Modifications in Glass Ionomer Cements: Nano-Sized Fillers and Bioactive Nanoceramics
Najeeb, S., Khurshid, Z., Zafar, M., Khan, A., Zohaib, S., Martí, J., Sauro, S., Matinlinna, J., & Rehman, I. (2016) · International Journal of Molecular Sciences · doi:10.3390/ijms17071134 · Cited by 226
“%) nano particles (nTiO2) to GIC powder has been shown to improve mechanical properties and anti-bacterial effects of the set material [69,70].”
BackgroundChen, J., Zhao, Q., Peng, J., Yang, X., Yu, D., & Zhao, W. (2020) · Journal of Dentistry · doi:10.1016/j.jdent.2020.103332 · Cited by 95
Metadata
- Authors
- GARCIA-CONTRERAS, R., SCOUGALL-VILCHIS, R. J., CONTRERAS-BULNES, R., SAKAGAMI, H., MORALES-LUCKIE, R. A., & NAKAJIMA, H.
- Venue
- Journal of Applied Oral Science
- Publisher
- FapUNIFESP (SciELO)
- Published
- 2015-06
- Volume
- 23
- Issue
- 3
- Pages
- 321-328
- ISSN
- 1678-7757 (ISSN-L)
- OpenAlex
- W1910911133
- Cited by
- 185
- References
- 0
- FWCI
- 16.41
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical, antibacterial and bond strength properties of nano-titanium-enriched glass ionomer cement. https://app.cochat.ai/papers/10.1590/1678-775720140496
- The paper
- GARCIA-CONTRERAS, R., SCOUGALL-VILCHIS, R. J., CONTRERAS-BULNES, R., SAKAGAMI, H., MORALES-LUCKIE, R. A., & NAKAJIMA, H. (2015). Mechanical, antibacterial and bond strength properties of nano-titanium-enriched glass ionomer cement. Journal of Applied Oral Science. https://doi.org/10.1590/1678-775720140496
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.