Determinação direta de selênio em água de coco e em leite de coco utilizando espectrometria de absorção atômica com atomização eletrotérmica em forno de grafite
Open accessThe DOI matches its Crossref record.
Abstract
ING GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY.Selenium is both essential and toxic to man and animals, depending on the concentration and the ingested form.Most fruits and vegetables are poor sources of selenium, but coconut can be a good selenium source.Samples were suspended (1 + 4 v/v) in a mixture of tertiary amines soluble in water (10% v/v CFA-C).This simple sample treatment avoided contamination and decreased the analysis time.The standard additions method was adopted for quantification.The action of the autosampler was improved by the presence of the amines mixture in the suspension.A Varian model AA-800 atomic absorption spectrometer equipped with a graphite furnace and a GTA 100 autosampler was used for selenium determination in coconut water and coconut milk.Background correction was performed by means of the Zeeman effect.Pyrolytically coated graphite tubes were employed.Using Pd as chemical modifier, the pyrolysis and the atomization temperatures were set at 1400 and 2200 o C, respectively.For six samples, the selenium concentration in coconut water varied from 6.5 to 21.0 µg L -1 and in coconut milk from 24.2 to 25.1 µg L -1 .The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values are in the 99.5-102.3%range.The main advantage of the proposed method is that it can be directly applied without sample decomposition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Licata, P., Trombetta, D., Cristani, M., Giofrè, F., Martino, D., Calò, M., & Naccari, F. (2004) · Environment International · doi:10.1016/s0160-4120(03)00139-9 · Cited by 253
Thermal inactivation of polyphenoloxidase and peroxidase in green coconut (Cocos nucifera) water
Murasaki‐Aliberti, N. D. C., Da Silva, R. M. S., Gut, J. A. W., & Tadini, C. C. (2009) · International Journal of Food Science & Technology · doi:10.1111/j.1365-2621.2009.02100.x · Cited by 46
de Sousa, R. A., Silva, J. C. J., Baccan, N., & Cadore, S. (2005) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2004.02.012 · Cited by 43
Halim, H. H., Williams Dee, E., Pak Dek, M. S., Hamid, A. A., Ngalim, A., Saari, N., & Jaafar, A. H. (2018) · International Journal of Food Properties · doi:10.1080/10942912.2018.1522329 · Cited by 41
“10 μg/100 mL).([35]) In the present work, the highest potassium content in CW samples from all varieties and maturities is in agreement with that of previous studies.”
ResultComposition, Properties and Reactions of Coconut Water
Rethinam, P., & Krishnakumar, V. (2022) · Coconut Water · doi:10.1007/978-3-031-10713-9_4 · Cited by 9
Metadata
- Authors
- Aleixo, P. C., Nóbrega, J. A., Santos Júnior, D., & Muller, R. C. S.
- Venue
- Química Nova
- Publisher
- FapUNIFESP (SciELO)
- Published
- 2000-06
- Volume
- 23
- Issue
- 3
- Pages
- 310-312
- ISSN
- 0100-4042 (ISSN-L)
- OpenAlex
- W1972934412
- Cited by
- 30
- References
- 0
- FWCI
- 1.50
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determinação direta de selênio em água de coco e em leite de coco utilizando espectrometria de absorção atômica com atomização eletrotérmica em forno de grafite. https://app.cochat.ai/papers/10.1590/s0100-40422000000300005
- The paper
- Aleixo, P. C., Nóbrega, J. A., Santos Júnior, D., & Muller, R. C. S. (2000). Determinação direta de selênio em água de coco e em leite de coco utilizando espectrometria de absorção atômica com atomização eletrotérmica em forno de grafite. Química Nova. https://doi.org/10.1590/s0100-40422000000300005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.