The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Reference values for lung function tests: III. Carbon monoxide diffusing capacity (transfer factor)
Open accessAbstract
Carbon monoxide diffusing capacity (DLCO) or transfer factor (TLCO) is a particularly useful test of the appropriateness of gas exchange across the lung alveolocapillary membrane. With the purpose of establishing predictive equations for DLCO using a non-smoking sample of the adult Brazilian population, we prospectively evaluated 100 subjects (50 males and 50 females aged 20 to 80 years), randomly selected from more than 8,000 individuals. Gender-specific linear prediction equations were developed by multiple regression analysis with single breath (SB) absolute and volume-corrected (VA) DLCO values as dependent variables. In the prediction equations, age (years) and height (cm) had opposite effects on DLCOSB (ml min-1 mmHg-1), independent of gender (-0.13 (age) + 0.32 (height) - 13.07 in males and -0.075 (age) + 0.18 (height) + 0.20 in females). On the other hand, height had a positive effect on DLCOSB but a negative one on DLCOSB/ VA (P < 0.01). We found that the predictive values from the most cited studies using predominantly Caucasian samples were significantly different from the actually measured values (P < 0.05). Furthermore, oxygen uptake at maximal exercise (VO2max) correlated highly to DLCOSB (R = 0.71, P < 0.001); this variable, however, did not maintain an independent role to explain the VO2max variability in the multiple regression analysis (P > 0.05). Our results therefore provide an original frame of reference for either DLCOSB or DLCOSB/VA in Brazilian males and females aged 20 to 80 years, obtained from the standardized single-breath technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Obesity on Respiratory Function
Ray, C. S., Sue, D. Y., Bray, G., Hansen, J. E., & Wasserman, K. (1983) · American Review of Respiratory Disease · doi:10.1164/arrd.1983.128.3.501 · Cited by 558
Diffusing capacity dependent on lung volume and age in normal subjects
Stam, H., Hrachovina, V., Stijnen, T., & Versprille, A. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.6.2356 · Cited by 105
Cited by
Neder, J. A., Andreoni, S., Lerario, M. C., & Nery, L. E. (1999) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x1999000600007 · Cited by 1,072
Self-citationReference values for lung function tests: I. Static volumes
Neder, J. A., Andreoni, S., Castelo-Filho, A., & Nery, L. E. (1999) · Brazilian Journal of Medical and Biological Research · doi:10.1590/s0100-879x1999000600006 · Cited by 333
Self-citationRespiratory muscle unloading improves leg muscle oxygenation during exercise in patients with COPD
Borghi-Silva, A., Oliveira, C. C., Carrascosa, C., Maia, J., Berton, D. C., Queiroga, F., Ferreira, E. M., Almeida, D. R., Nery, L. E., & Neder, J. A. (2008) · Thorax · doi:10.1136/thx.2007.090167 · Cited by 156
“In conclusion, respiratory muscle unloading by PAV was associated with increased peripheral muscle oxygenation under stable systemic oxygen delivery during high-intensity constant work rate exercise in patients with moderate to severe COPD.”
BackgroundInfluentialSelf-citationChiappa, G. R., Queiroga, F., Meda, E., Ferreira, L. F., Diefenthaeler, F., Nunes, M., Vaz, M. A., Machado, M. C. L., Nery, L. E., & Neder, J. A. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200811-1793oc · Cited by 122
“Recorded values were compared with those predicted for the adult Brazilian population (20, 21).”
BackgroundSelf-citationBaldi, B. G., Samano, M. N., Campos, S. V., de Oliveira, M. R., Junior, J. E. A., Carraro, R. M., Teixeira, R. H. O. B., Minguini, I. P., Burlina, R., Pato, E. Z. S., et al. (2017) · Lung · doi:10.1007/s00408-017-0045-y · Cited by 16
Metadata
- Authors
- Neder, J. A., Andreoni, S., Peres, C., & Nery, L. E.
- Venue
- Brazilian Journal of Medical and Biological Research
- Publisher
- FapUNIFESP (SciELO)
- Published
- 1999-06
- Volume
- 32
- Issue
- 6
- Pages
- 729-737
- ISSN
- 0100-879X (ISSN-L)
- OpenAlex
- W2147841420
- Cited by
- 176
- References
- 2
- FWCI
- 0.59
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reference values for lung function tests: III. Carbon monoxide diffusing capacity (transfer factor). https://app.cochat.ai/papers/10.1590/s0100-879x1999000600008
- The paper
- Neder, J. A., Andreoni, S., Peres, C., & Nery, L. E. (1999). Reference values for lung function tests: III. Carbon monoxide diffusing capacity (transfer factor). Brazilian Journal of Medical and Biological Research. https://doi.org/10.1590/s0100-879x1999000600008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.