CoChat

A Review of Blood Substitutes: Examining The History, Clinical Trial Results, and Ethics of Hemoglobin-Based Oxygen Carriers

Open access
Chen, Jiin-Yu, Scerbo, Michelle, Kramer, George · 2009 · Clinics
Cited by 216

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

The complications associated with acquiring and storing whole blood for transfusions have launched substantial efforts to develop a blood substitute. The history of these efforts involves a complicated mixture of science, ethics, and business. This review focuses on clinical trials of the three hemoglobin-based oxygen carriers (HBOC) that have progressed to Phase II or III clinical trials: He-mAssist (Baxter; Deerfield, IL, US), PolyHeme (Northfield; Evanston, IL, US), and Hemopure (Biopure; Cambridge, MA, US). Published animal studies and clinical trials carried out in a perioperative setting have demonstrated that these products successfully transport and deliver oxygen, but all may induce hypertension and lead to unexpectedly low cardiac outputs. Overall, these studies suggest that HBOCs resulted in only modest blood saving during and after surgery, no improvement in mortality and an increased incidence of adverse reactions. To date, the results from these perioperative studies have not led to regulatory approval. All three companies instead chose to focus their efforts on large trials of trauma patients in the pre-hospital setting.Baxter abandoned the development of HemAssist after a trial in the U.S. was prematurely halted when the first 100 patients showed significantly increased mortality rates as compared to patients treated with blood products. Northfield's PolyHeme trial demonstrated a non-significant trend towards increased mortality and a very modest reduction in the subsequent need for blood. The testing of Biopure's Hemopure for trauma patients has been halted for several years because of FDA concerns over trial design and study justification. Ethical concerns have also been raised regarding the design and implementation of all HBOC clinical trials.Thus, the available evidence suggests that HemAssist, Polyheme, and Hemopure are associated with a significant level of cardiovascular dysfunction. The next generation of HBOCs remains under development.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1590/s1807-59322009000800016

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 216

Metadata

Authors
Chen, J.-Y., Scerbo, M., & Kramer, G.
Venue
Clinics
Publisher
Elsevier BV
Published
2009-08
Volume
64
Issue
8
Pages
803-813
ISSN
1807-5932 (ISSN-L)
OpenAlex
W2161491970
Cited by
216
References
16
FWCI
5.79
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Review of Blood Substitutes: Examining The History, Clinical Trial Results, and Ethics of Hemoglobin-Based Oxygen Carriers. https://app.cochat.ai/papers/10.1590/s1807-59322009000800016
The paper
Chen, J.-Y., Scerbo, M., & Kramer, G. (2009). A Review of Blood Substitutes: Examining The History, Clinical Trial Results, and Ethics of Hemoglobin-Based Oxygen Carriers. Clinics. https://doi.org/10.1590/s1807-59322009000800016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.