Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 174

The DOI matches its Crossref record.

Utilizing Optical Tomography with Ultrasound Localization to Image Heterogeneous Hemoglobin Distribution in Large Breast Cancers

Open access
Zhu, Quing, Kurtzman, Scott H., Hegde, Poornima, Tannenbaum, Susan, Kane, Mark, Huang, Minming, Chen, Nan Guang, Jagjivan, Bipin, Zarfos, Kristen · 2005 · Neoplasia

Abstract

PURPOSE: Angiogenesis in advanced breast cancers is highly distorted and heterogeneous. Noninvasive imaging that can monitor angiogenesis may be invaluable initially for diagnosis and then for assessing tumor response to treatment. By combining ultrasound (US) and near-infrared (NIR) optical imaging, a reliable new technique has emerged for localizing and characterizing tumor angiogenesis within the breast. METHODS: This new technique employs a commercial US transducer coupled with an array of NIR optical fibers mounted on a hand-held probe. The US image is used for lesion localization and for guiding optical imaging reconstruction. Optical sensors are used for imaging tumor total hemoglobin distribution, which is directly related to tumor angiogenesis. RESULTS: Six large breast carcinomas were studied and microvessel density count was then performed on tissue samples obtained from these cancers. Two patients had locally advanced breast cancers and received neoadjuvant chemotherapy for 3 months. In one patient, before chemotherapy, the total hemoglobin distribution showed a high concentration at the cancer periphery; the distribution was later confined to the core area after 3 months of treatment. In another patient, as treatment progressed, the maximum hemoglobin concentration decreased from 255.3, to 147.5, to 76.9 micromol/l with an associated reduction in spatial extension. The other four patients had cancers of 2.0 to 3.0 cm in size and were imaged either at the time of core biopsy or definitive surgery. The histologic microvessel density counts from these tumor samples correlate to hemoglobin distributions with a correlation coefficient of 0.64 (P < .05). CONCLUSION: These initial results suggest that this new imaging technique may have great potential in imaging the heterogeneous vascular distribution of larger breast cancers in vivo and in monitoring treatment-related changes in angiogenesis during chemotherapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1593/neo.04526

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 174

Metadata

Authors
Zhu, Q., Kurtzman, S. H., Hegde, P., Tannenbaum, S., Kane, M., Huang, M., Chen, N. G., Jagjivan, B., & Zarfos, K.
Venue
Neoplasia
Publisher
Elsevier BV
Published
2005-03
Volume
7
Issue
3
Pages
263-270
ISSN
1476-5586 (ISSN-L)
OpenAlex
W1971666287
Cited by
174
References
0
FWCI
15.00
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Utilizing Optical Tomography with Ultrasound Localization to Image Heterogeneous Hemoglobin Distribution in Large Breast Cancers. https://app.cochat.ai/papers/10.1593/neo.04526
The paper
Zhu, Q., Kurtzman, S. H., Hegde, P., Tannenbaum, S., Kane, M., Huang, M., Chen, N. G., Jagjivan, B., & Zarfos, K. (2005). Utilizing Optical Tomography with Ultrasound Localization to Image Heterogeneous Hemoglobin Distribution in Large Breast Cancers. Neoplasia. https://doi.org/10.1593/neo.04526

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.