Estimation of Human Internal Temperature from Wearable Physiological Sensors
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We evaluated a Kalman filter (KF) approach to modeling the physiology of internal temperature viewed through “noisy” non-invasive observations of heart rate. Human core body temperature (Tcore) is an important measure of thermal state, e.g., hypo- or hyperthermia, but is difficult to measure using non-invasive wearable sensors. We estimated parameters for a discrete KF model from data collected during several Military training events and from distance runners (n=38). Model performance was evaluated in 25 physically-active subjects who participated in various laboratory and field studies involving exercise of 2-to-8 h duration at ambient temperatures of 20 to 40°C. Overall, the KF model’s estimate of Tcore had a root mean square error of 0.30±0.13 ºC from the observed Tcore, and was within ± 0.5 ºC over 85% of the time. The benefit of the KF approach is that it requires only one input while current state of the art models typically require multiple inputs including individual anthropometrics, metabolic rate, clothing characteristics, and environmental conditions. This state estimation problem in computational physiology illustrates the potential for collaboration between the artificial intelligence and ambulatory physiological monitoring communities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A non-invasive device to continuously determine heat strain in humans
Gunga, H.-C., Sandsund, M., Reinertsen, R. E., Sattler, F., & Koch, J. (2008) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2008.03.004 · Cited by 129 · cited 1×
“However, classic methods for monitoring Tcore, such as rectal thermistors and esophageal probes, are not appropriate for an ambulatory setting (Gunga et al. 2008).”
Method
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
“ambient temperature and humidity also play an important role in this body temperature regulation mechanism [65,66].”
BackgroundGaura, E., Kemp, J., & Brusey, J. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2254485 · Cited by 32
Metadata
- Authors
- Buller, M., Tharion, W., Hoyt, R., & Jenkins, O.
- Venue
- Proceedings of the AAAI Conference on Artificial Intelligence
- Published
- 2010-07-11
- Volume
- 24
- Issue
- 2
- Pages
- 1763-1768
- ISSN
- 2159-5399 (ISSN-L)
- 2374-3468
- OpenAlex
- W184501245
- Cited by
- 47
- References
- 1
- FWCI
- 27.97
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of Human Internal Temperature from Wearable Physiological Sensors. https://app.cochat.ai/papers/10.1609/aaai.v24i2.18809
- The paper
- Buller, M., Tharion, W., Hoyt, R., & Jenkins, O. (2010). Estimation of Human Internal Temperature from Wearable Physiological Sensors. Proceedings of the AAAI Conference on Artificial Intelligence. https://doi.org/10.1609/aaai.v24i2.18809
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.