Cited by 206Thermal properties of materialsHeat Transfer and Numerical MethodsThermography and Photoacoustic Techniques

MEASURING THE THERMAL CONDUCTIVITY OF THIN FILMS: 3 OMEGA AND RELATED ELECTROTHERMAL METHODS

Dames, Chris·2013·Annual Review of Heat Transfer

Abstract

This review describes the major electrothermal methods for measuring the thermal conductivity of thin films in both cross-plane and in-plane directions. These methods use microfabricated metal lines for joule heating and resistance thermometry. The 3ω method for crossplane measurements is described thoroughly, along with a related DC method. For in-plane measurements, several methods are presented for suspended and supported films. Various practical matters are also discussed, including parasitic thermal resistances, background subtraction, and instrumentation issues. The review contains sufficient detail to be accessible to researchers new to the field of thin film thermal conductivity measurements, and also includes information relevant for 3ω measurements of bulk substrates. The review also contains new analytical results for the variable-linewidth 3ω method, the related heat spreader method, and the distinction between isothermal and constant flux heater approximations.

Integrity signals

Registry

Crossref · 10.1615/annualrevheattransfer.v16.20

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Transient methods (transient hot wire, transient plane source, laser flash, 3-ω, transient thermoreflectance) provide higher throughput of measurement with advantages: easier application to small millimeter-sized samples, relatively short measurement time, and smaller unwanted heat loss due to controllable thermal penetration depth.

    “In comparison, transient methods such as the transient hot wire (ASTM C518), transient plane source, 3 the laser flash method, 4 the 3-ω method, 5, 6 and the transient thermoreflectance methods 7, 8 provide higher throughput of measurement with several advantages.”

Cited by

Sorted by citations

Authors
Dames, C.
Affiliations
University of California, Berkeley (US)
Corresponding author
Dames, Chris
Venue
Annual Review of Heat Transfer
Publisher
Begell House
Published
2013
Volume
16
Issue
1
Pages
7-49
ISSN
1049-0787 (ISSN-L)
OpenAlex
W2332287436
Cited by
206
References
0
Citations by year
2026: 21 · 2025: 25 · 2024: 21 · 2023: 16 · 2022: 23 · 2021: 18 · 2020: 14 · 2019: 11 · 2018: 16 · 2017: 19 · 2016: 12 · 2015: 7 · 2014: 1 · 2013: 1 · 2012: 1
FWCI
3.16
Type
journal article
Language
en
Open access
closed
Locations
Annual Reviews of Heat Transfer (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
  • Physical Sciences › Engineering › Computational Mechanics › Heat Transfer and Numerical Methods
  • Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
Keywords
thin film thermal conductivity, 3ω method, through-plane thermal conductivity, in-plane thermal conductivity, Joule heating, resistance thermometry, suspended films, supported films, background subtraction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review