Response Evaluation of Gastrointestinal Stromal Tumors
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Clinical management of patients with gastrointestinal stromal tumors (GISTs) has dramatically changed with the introduction of novel therapeutics, such as imatinib mesylate. This has created a need to re-evaluate the existing criteria used to assess treatment response. The current Response Evaluation Criteria in Solid Tumors are based on unidimensional tumor size, and do not take into account changes in responding GISTs such as a decrease in tumor density and decrease in the number of intratumoral vessels with computed tomography (CT). Positron emission tomography (PET) has been found to be highly sensitive in detecting early response, and to be useful in predicting long-term response to imatinib in patients with metastatic GIST; however, widespread use of PET is limited because of a lack of scanner availability and cost constraints. Modified CT criteria using a combination of tumor density and tumor size are promising in early response evaluation, and have excellent prognostic value. Identifying appropriate treatment response criteria is essential to optimize treatment for patients with GIST.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New Guidelines to Evaluate the Response to Treatment in Solid Tumors
Therasse, P., Arbuck, S. G., Eisenhauer, E. A., Wanders, J., Kaplan, R. S., Rubinstein, L., Verweij, J., Van Glabbeke, M., van Oosterom, A. T., Christian, M. C., et al. (2000) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/92.3.205 · Cited by 15,660 · cited 1×
“The current international Response Evaluation Criteria in Solid Tumors (RECIST) identify computed tomography (CT) and magnetic resonance imaging (MRI) as the best available and most reproducible methods for measuring target lesions [ 4 ].”
MethodChoi, H., Charnsangavej, C., Faria, S. C., Macapinlac, H. A., Burgess, M. A., Patel, S. R., Chen, L. L., Podoloff, D. A., & Benjamin, R. S. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.07.3049 · Cited by 1,520 · cited 1×
“® (Table 3) [ 8 ]. These modified CT criteria have been shown to be highly capable of separating responders and nonresponders and provide an excellent prognostic indicator in terms of progression-free survival (Fig. 4) [9], although further validation is needed in larger populations.”
BackgroundSelf-citationWe Should Desist Using RECIST, at Least in GIST
Benjamin, R. S., Choi, H., Macapinlac, H. A., Burgess, M. A., Patel, S. R., Chen, L. L., Podoloff, D. A., & Charnsangavej, C. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.07.3411 · Cited by 559 · cited 1×
“These modified CT criteria have been shown to be highly capable of separating responders and nonresponders and provide an excellent prognostic indicator in terms of progression-free survival (Fig. 4) [ 9 ], although further validation is needed in larger populations.”
BackgroundSelf-citationChoi, H., Charnsangavej, C., Faria, S. D. C., Tamm, E. P., Benjamin, R. S., Johnson, M. M., Macapinlac, H. A., & Podoloff, D. A. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.6.01831619 · Cited by 459
Self-citationMiettinen, M., & Lasota, J. P. (2003) · PubMed · Cited by 398
Malignant biphasic uterine tumours: carcinosarcomas or metaplastic carcinomas?
McCluggage, W. G. (2002) · Journal of Clinical Pathology · doi:10.1136/jcp.55.5.321 · Cited by 379
Xie, H. Y., Choi, H., Loyer, E. M., Benjamin, R. S., Trent, J. C., & Charnsangavej, C. (2006) · Radiographics · doi:10.1148/rg.262055097 · Cited by 239 · cited 2×
“Contrast-enhanced CT is a powerful technique for GIST diagnosis, allowing for characterization of tumors [ 7 ] (Fig. 1). Once GIST is treated, the tumor size usually decreases upon response.”
BackgroundMethodSelf-citationGastrointestinal Stromal Tumors
Strickland, L. B., Letson, G. D., & Muro‐Cacho, C. (2001) · Cancer Control · doi:10.1177/107327480100800305 · Cited by 95
Cited by
Chan, D. L., Pavlakis, N., Schembri, G. P., Bernard, E. J., Hsiao, E., Hayes, A., Barnes, T., Diakos, C., Khasraw, M., Samra, J., et al. (2017) · Theranostics · doi:10.7150/thno.18068 · Cited by 297
The Lessons of GIST—PET and PET/CT: A New Paradigm for Imaging
Van den Abbeele, A. D. (2008) · The Oncologist · doi:10.1634/theoncologist.13-s2-8 · Cited by 292
Response Criteria in Oncologic Imaging: Review of Traditional and New Criteria
Tirkes, T., Hollar, M. A., Tann, M., Kohli, M. D., Akisik, F., & Sandrasegaran, K. (2013) · RadioGraphics · doi:10.1148/rg.335125214 · Cited by 279
Edeline, J., Boucher, E., Rolland, Y., Vauléon, E., Pracht, M., Perrin, C., Le Roux, C., & Raoul, J. (2012) · Cancer · doi:10.1002/cncr.26255 · Cited by 275
Kantartzis, K., Thamer, C., Peter, A., Machann, J., Schick, F., Schraml, C., Konigsrainer, A., Konigsrainer, I., Krober, S., Niess, A., et al. (2009) · Gut · doi:10.1136/gut.2008.151977 · Cited by 273
Nishino, M., Jagannathan, J. P., Krajewski, K. M., O’Regan, K., Hatabu, H., Shapiro, G., & Ramaiya, N. H. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.7483 · Cited by 180
“The use of Choi criteria or similar modified criteria incorporating CT attenuation changes have also been studied and proposed in other solid tumors treated with targeted therapies, including other sarcomas, as well as renal cell carcinomas and hepatocellular carcinomas treated with antiangiogenic therapy [21–23].”
BackgroundWardelmann, E., Haas, R. L., Bovée, J. V. M. G., Terrier, P., Lazar, A., Messiou, C., LePechoux, C., Hartmann, W., Collin, F., Fisher, C., et al. (2016) · European Journal of Cancer · doi:10.1016/j.ejca.2015.09.021 · Cited by 158
FDG PET/CT-based response assessment in malignancies
Parihar, A. S., Dehdashti, F., & Wahl, R. L. (2023) · RadioGraphics · doi:10.1148/rg.220122 · Cited by 53
“For example, a change in the pattern of internal enhancement is one of the early and key signatures of response in gastrointestinal stromal tumors (21).”
Metadata
- Authors
- Choi, H.
- Venue
- The Oncologist
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-04-01
- Volume
- 13
- Issue
- S2
- Pages
- 4-7
- ISSN
- 1083-7159 (ISSN-L)
- 1549-490X
- OpenAlex
- W2139020082
- Cited by
- 238
- References
- 8
- FWCI
- 14.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.