Slowing the Increase in the Population Dose Resulting from CT Scans
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The annual number of CT scans in the U.S. is now over 70 million. The concern is that organ doses from CT are typically far larger than those from conventional X-ray examinations, and there is epidemiological evidence of a small but significant increased cancer risk at typical CT doses. Because CT is a superb diagnostic tool and because individual CT risks are small, when a CT scan is clinically indicated, the CT benefit/risk balance is by far in the patient's favor. Nevertheless, CT should operate under the ALARA (As Low As Reasonably Achievable) principle, and opportunities exist to reduce the significant population dose associated with CT without compromising patient care. The first opportunity is to reduce the dose per scan, and improved technology has much potential here. The second opportunity is selective replacement of CT with other modalities, such as for many head and spinal examinations (with MRI), and for diagnosing appendicitis (selective use of ultrasound + CT). Finally, a fraction of CT scans could be avoided entirely, as indicated by CT decision rules: Clinical decision rules for CT use represent a powerful approach for slowing down the increase in CT use, because they have the potential to overcome some of the major factors that result in some CT scans being undertaken when they are potentially not clinically helpful. In the U.S. and potentially elsewhere, legislative approaches are a possible option, to improve quality control and reduce clinically unneeded CT use, and it is also possible that upcoming changes in heath care economics will tend to slow the increase in such CT use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842 · cited 1×
“There have been considerable technological advances in reducing the dose per scan (20), which is especially important for children.”
Research works printed but not linked: 49
- 10.1259/bjr/01948454 · DOI · Paper page
- 10.1056/NEJMra072149 · DOI · Paper page
- Stern S., 2001, Radiology, 221, 161
- 10.1088/0952-4746/20/4/301 · DOI · Paper page
- Black W. C., 2007, Cancer, 110, 2370, 10.1002/cncr.23059 · DOI
- Waugh N., 2006, Health Technol. Assess, 10, 1, 10.3310/hta10390 · DOI
- Pickhardt P. J., 2007, Radiol. Clin. North Am, 45, 361, 10.1016/j.rcl.2007.03.011 · doi:10.1016/j.rcl.2007.03.011
- 10.1148/radiol.2372041741 · DOI · Paper page
- Winslow J. E., 2008, Ann. Emerg. Med, 52, 93, 10.1016/j.annemergmed.2007.12.019 · DOI
- 10.1148/radiol.2511081296 · DOI · Paper page
- Preston D. L., 2007, Radiat. Res, 168, 1, 10.1667/RR0763.1 · DOI · Paper page
- Pierce D. A., 2000, Radiat. Res, 154, 178, 10.1667/0033-7587(2000)154[0178:RRCRAL]2.0.CO;2 · DOI · Paper page
- Broder J., 2007, Emerg. Radiol, 14, 227, 10.1007/s10140-007-0618-9 · DOI · Paper page
- Frush D. P., 2002, Am. J. Roentgenol, 178, 721, 10.2214/ajr.178.3.1780721 · DOI
- Kalender W. A., 2008, Phys. Med, 24, 71, 10.1016/j.ejmp.2008.01.012 · DOI · Paper page
- Hausleiter J., 2009, J. Am. Med. Assoc, 301, 500, 10.1001/jama.2009.54 · DOI · Paper page
- Arch M. E., 2008, Am. J. Roentgenol, 191, 611, 10.2214/AJR.07.2989 · doi:10.2214/ajr.07.2989
- Clarke J. C., 2001, Br. J. Radiol, 74, 926, 10.1259/bjr.74.886.740926 · DOI
- Deck M. D., 1989, Clin. Imaging, 13, 2, 10.1016/0899-7071(89)90120-4 · doi:10.1016/0899-7071(89)90120-4
- Malfair D., 2007, Magn. Reson. Imaging Clin. N. Am, 15, 221, 10.1016/j.mric.2007.04.001 · doi:10.1016/j.mric.2007.04.001
- 10.1002/jmri.20895 · DOI · Paper page
- Oikarinen H., 2009, Eur. Radiol, 19, 1161, 10.1007/s00330-008-1256-7 · DOI
- Lin M. F., 2008, Curr. Opin. Gastroenterol, 24, 135, 10.1097/MOG.0b013e3282f49b14 · doi:10.1097/mog.0b013e3282f49b14
- Ward J., 1997, Clin. Radiol, 52, 109, 10.1016/S0009-9260(97)80102-X · doi:10.1016/s0009-9260(97)80102-x
- Stein S. C., 2009, Ann. Emerg. Med, 53, 180, 10.1016/j.annemergmed.2008.01.002 · DOI
- Smits M., 2005, J. Am. Med. Assoc, 294, 1519, 10.1001/jama.294.12.1519 · DOI · Paper page
- Hadley J. L., 2006, Am. J. Roentgenol, 186, 937, 10.2214/AJR.05.0041 · DOI
- Garcia Peña B. M., 2004, Pediatrics, 113, 24, 10.1542/peds.113.1.24 · DOI
- Eagles D., 2008, Acad. Emerg. Med, 15, 177, 10.1111/j.1553-2712.2008.00035.x · DOI
- Reed M. H., 2008, Pediatr. Radiol, 38, S660, 10.1007/s00247-008-0982-y · doi:10.1007/s00247-008-0982-y
- Broder J., 2007, J. Emerg. Med, 33, 161, 10.1016/j.jemermed.2006.12.035 · DOI
- Klassen T. P., 2000, Acad. Emerg. Med, 7, 739, 10.1111/j.1553-2712.2000.tb02260.x · doi:10.1111/j.1553-2712.2000.tb02260.x
- Smink D. S., 2004, J. Pediatr. Surg, 39, 458, 10.1016/j.jpedsurg.2003.11.015 · DOI
- Jindal A., 2002, World J. Surg, 26, 13, 10.1007/s00268-001-0174-5 · doi:10.1007/s00268-001-0174-5
- Abcarian P. W., 2004, AJR Am. J. Roentgenol, 182, 1377, 10.2214/ajr.182.6.1821377 · doi:10.2214/ajr.182.6.1821377
- McKay R., 2007, Am. J. Emerg. Med, 25, 489, 10.1016/j.ajem.2006.08.020 · DOI · Paper page
- Amis E. S., 2007, J. Am. Coll. Radiol, 4, 272, 10.1016/j.jacr.2007.03.002 · DOI · Paper page
- Ghanta M. K., 2002, Am. Surg, 68, 563, 10.1177/000313480206800610 · doi:10.1177/000313480206800610
- Bautista A. B., 2009, Am. J. Roentgenol, 192, 1581, 10.2214/AJR.08.1622 · DOI
- Eagles D., 2008, Acad. Emerg. Med, 15, 1256, 10.1111/j.1553-2712.2008.00265.x · DOI
- Blachar A., 2006, J. Am. Coll. Radiol, 3, 851, 10.1016/j.jacr.2006.04.005 · DOI
- Sistrom C. L., 2009, Radiology, 251, 147, 10.1148/radiol.2511081174 · DOI · Paper page
- Hendel R. C., 2008, JACC Cardiovasc. Imaging, 1, 241, 10.1016/j.jcmg.2008.01.008 · doi:10.1016/j.jcmg.2008.01.008
- Mitchell J. M., 2009, Med. Care Res. Rev, 66, 339, 10.1177/1077558709332055 · DOI
- Smulowitz P. B., 2009, Am. J. Emerg. Med, 27, 328, 10.1016/j.ajem.2008.03.012 · DOI
- Larson D. B., 2007, Am. J. Roentgenol, 189, 271, 10.2214/AJR.07.2248 · DOI
- Linton O. W., 2003, Am. J. Roentgenol, 181, 321, 10.2214/ajr.181.2.1810321 · DOI · Paper page
- Bulas D. I., 2009, Am. J. Roentgenol, 192, 1176, 10.2214/AJR.08.2218 · DOI
- Schwartz L. M., 2004, J. Am. Med. Assoc, 291, 71, 10.1001/jama.291.1.71 · DOI · Paper page
Cited by
Papa, L., Lewis, L. M., Falk, J. L., Zhang, Z., Silvestri, S., Giordano, P., Brophy, G. M., Demery, J. A., Dixit, N. K., Ferguson, I., et al. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2011.08.021 · Cited by 332
Chu, L. C., Park, S., Kawamoto, S., Fouladi, D. F., Shayesteh, S., Zinreich, E. S., Graves, J. S., Horton, K. M., Hruban, R. H., Yuille, A. L., et al. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.18.20901 · Cited by 193
A review of patient dose and optimisation methods in adult and paediatric CT scanning
Dougeni, E., Faulkner, K., & Panayiotakis, G. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.05.025 · Cited by 185
Effects of ionizing radiation on DNA methylation: from experimental biology to clinical applications
Miousse, I. R., Kutanzi, K. R., & Koturbash, I. (2017) · International Journal of Radiation Biology · doi:10.1080/09553002.2017.1287454 · Cited by 167
Franck, C., Vandevoorde, C., Goethals, I., Smeets, P., Achten, E., Verstraete, K., Thierens, H., & Bacher, K. (2016) · European Radiology · doi:10.1007/s00330-015-4091-7 · Cited by 43
“This study focuses on children, since dose reduction in paediatric radiology is a top priority [5, 12, 26, 27].”
Background
Metadata
- Authors
- Brenner, D. J.
- Venue
- Radiation Research
- Publisher
- Radiation Research Society
- Published
- 2010-12
- Volume
- 174
- Issue
- 6b
- Pages
- 809-815
- ISSN
- 0033-7587 (ISSN-L)
- 1938-5404
- OpenAlex
- W2164269215
- Cited by
- 134
- References
- 1
- FWCI
- 10.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Slowing the Increase in the Population Dose Resulting from CT Scans. https://app.cochat.ai/papers/10.1667/rr1859.1
- The paper
- Brenner, D. J. (2010). Slowing the Increase in the Population Dose Resulting from CT Scans. Radiation Research. https://doi.org/10.1667/rr1859.1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.