CoChat

Corticotrophin-releasing hormone (CRH)-binding protein interference with CRH antibody binding: implications for direct CRH immunoassay

Linton, E A, Perkins, A V, Hagan, P, Poole, S, Bristow, A F, Tilders, F, Corder, R, Wolfe, C D A · 1995 · Journal of Endocrinology
Cited by 37

The DOI matches its Crossref record.

Abstract

Direct immunoassay of plasma corticotrophin-releasing hormone (CRH) is potentially subject to interference from high levels of CRH-binding protein (CRH-BP) that exist in the human circulation. In this study, we tested the effect of CRH-free, native CRH-BP (6·4 nmol/l) purified from human plasma, CRH-BP diluent alone, normal human plasma (containing 5·8 nmol endogenous CRH-BP/1) and normal sheep plasma (containing no CRH-BP) on the binding of 125 I-labelled CRH tracer to five N-terminal and four C-terminal CRH antibodies. All anti-(1–20)CRH N-terminal antibody dilution curves displayed marked inhibition of binding in the presence of purified CRH-BP and human plasma in comparison with the curves with the control diluent or sheep plasma. Almost no inhibition of binding was obtained with any of the C-terminal antibodies (all directed against epitopes within the last six amino acids of CRH) and the four dilution curves were nearly superimposable. Liquid-phase CRH IRMAs were then developed with different combinations of two of each of the N- and C-terminal antibodies, using radiolabelled IgG prepared from purified C-terminal antisera as tracer and raw N-terminal antisera as the link antibodies to the separating system. The addition of dilutions of purified CRH-BP over the range 1·25–20 nmol/l to the IRMA standard curve in assay buffer resulted in a dose-dependent reduction in the signal; with 5 nmol CRH-BP/1, a level commonly found in human plasma, the reduction in binding was 67% and 81% in two different IRMAs at a CRH concentration of 631 pmol/l. With endogenous CRH-BP in human plasma, a dose-dependent inhibition of binding similarly resulted, with the plasma containing the most CRH-BP causing the greatest inhibition. Since plasma CRH-BP levels in humans vary widely, direct plasma IRMA using these type of antibodies will give inaccurate results and initial extraction of the CRH is necessary. Methanol extraction of synthetic or endogenous CRH is shown to be both highly efficient and unaffected by variable amounts of endogenous or exogenous CRH-BP; it is therefore suitable as the first step in plasma CRH measurement by IRMA. Journal of Endocrinology (1995) 146, 45–53

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1677/joe.0.1460045

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Linton, E. A., Perkins, A. V., Hagan, P., Poole, S., Bristow, A. F., Tilders, F., Corder, R., & Wolfe, C. D. A.
Venue
Journal of Endocrinology
Published
1995-07
Volume
146
Issue
1
Pages
45-53
ISSN
  • 0022-0795 (ISSN-L)
  • 1479-6805
OpenAlex
W2057038749
Cited by
37
References
0
FWCI
1.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.