The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A new drying method of biological specimens for scanning electron microscopy: The t-butyl alcohol freeze-drying method.
Open accessAbstract
A simple drying method for biological materials for scanning electron microscopy was developed. Fixed specimens were immersed in t-butyl alcohol after dehydration through a graded series of ethanol. When the room temperature fell below the melting point of t-butyl alcohol (25.5 degrees C), liquidized alcohol obtained by warming was used. Specimens in the alcohol were then frozen in a refrigerator. They were placed in the bell jar of a vacuum evaporator and simply evacuated with a rotary pump. The samples were completely dried within 1 h after the frozen alcohol was sublimated in the vacuum. When examined by scanning electron microscopy (SEM), both surface and intracellular structures were demonstrated in three-dimension without any significant drying artifacts. Careful comparison of the results indicated that the SEM images obtained by this method were either superior or equal to those obtained by the critical point drying method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preparation of animal tissues for surface‐scanning electron microscopy
Boyde, A., & Wood, C. (1969) · Journal of Microscopy · doi:10.1111/j.1365-2818.1969.tb00709.x · Cited by 345
A Revised Tannin-Osmium Method for Non-Coated Scanning Electron Microscope Specimens
MURAKAMI, T. (1974) · Archivum histologicum japonicum · doi:10.1679/aohc1950.36.189 · Cited by 276
A preparation method for observing intracellular structures by scanning electron microscopy
Tanaka, K., & Mitsushima, A. (1984) · Journal of Microscopy · doi:10.1111/j.1365-2818.1984.tb00487.x · Cited by 183
The cytoplasmic filament system in critical point-dried whole mounts and plastic-embedded sections.
Ris, H. (1985) · The Journal of cell biology · doi:10.1083/jcb.100.5.1474 · Cited by 158
Effect on Tissue Volume of Various Methods of Fixation, Dehydration, and Embedding
Stowell, R. E. (1941) · Stain Technology · doi:10.3109/10520294109106200 · Cited by 80
Cited by
Surface micromachining for microelectromechanical systems
Bustillo, J. M., Howe, R. T., & Muller, R. S. (1998) · Proceedings of the IEEE · doi:10.1109/5.704260 · Cited by 644
High-porosity aerogels of high specific surface area prepared from nanofibrillated cellulose (NFC)
Sehaqui, H., Zhou, Q., & Berglund, L. A. (2011) · Composites Science and Technology · doi:10.1016/j.compscitech.2011.07.003 · Cited by 568
Review on the Aerogel-Type Oil Sorbents Derived from Nanocellulose
Liu, H., Geng, B., Chen, Y., & Wang, H. (2017) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.6b02301 · Cited by 347
Nishimura, T., Hattori, A., & Takahashi, K. (1999) · Journal of Animal Science · doi:10.2527/1999.77193x · Cited by 278
A Roadmap for 3D Metal Aerogels: Materials Design and Application Attempts
Jiang, X., Du, R., Hübner, R., Hu, Y., & Eychmüller, A. (2021) · Matter · doi:10.1016/j.matt.2020.10.001 · Cited by 124
Metadata
- Authors
- OSATAKE, H., & INOUÉ, T.
- Venue
- Archives of Histology and Cytology
- Published
- 1988
- Volume
- 51
- Issue
- 1
- Pages
- 53-59
- ISSN
- 0004-0681 (ISSN-L)
- 0914-9465
- 1349-1717
- OpenAlex
- W1971583235
- Cited by
- 409
- References
- 5
- FWCI
- 9.52
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new drying method of biological specimens for scanning electron microscopy: The t-butyl alcohol freeze-drying method. https://app.cochat.ai/papers/10.1679/aohc.51.53
- The paper
- OSATAKE, H., & INOUÉ, T. (1988). A new drying method of biological specimens for scanning electron microscopy: The t-butyl alcohol freeze-drying method. Archives of Histology and Cytology. https://doi.org/10.1679/aohc.51.53
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.