The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Preparation of animal tissues for surface‐scanning electron microscopy
Abstract
SUMMARY: This paper surveys common problems associated with the preparation of animal tissues so that natural or artificial surfaces may be studied in the scanning electron microscope (SEM). Problems arise because (1) we need to prepare surfaces free from extraneous solids in solution (e.g. mucus, blood, tissue fluid); (2) surfaces of simple sections generally do not reveal significant information so that other methods of ‘opening up’ internal organization must be developed; (3) we need to remove the preponderant tissue component—water—without significantly altering the remaining structure, which generally has a very low density, is fragile and is non‐conducting. In the case of natural, free surfaces to soft tissues, isolated cells or cultures the most useful approach seems to be (a) to wash with a suitable isotonic medium; (b) to fix with an aldehyde; (c) to harden with Parducz's (1967) OsO 4, HgCl 2 fixative. Artificial surfaces revealing details of internal organization are best prepared by dissecting and ripping aldehyde‐perfused and fixed tissue; the duration of fixation has been found to influence the location of the ripping planes in CNS. Enzymatic digestion may usefully be combined with dissection, but must be conducted before fixation. Wet tissue surface is least distorted following freeze drying from a non‐polar solvent (e.g. amyl acetate) which has substituted the tissue water. Critical‐point drying requires simple apparatus and is also generally satisfactory, but it does cause some bulk shrinkage. Specimens are best coated with a combination of carbon and gold to render them conducting: carbon because it is easily scattered and thus tends to cover very rough surfaces, and because it is tough and stabilizes the surface; gold because it is the most convenient heavy metal having high secondary‐electron emission to evaporate. Dried soft tissues have very low bulk densities, and beam‐penetration artifacts (bulk charging and edge artifacts) are therefore troublesome. These may be limited by working at as low an accelerating beam voltage as can be tolerated to achieve the required resolution. The preparation and examination of stereo‐pair micrographs is recommended as a routine because images can then be interpreted in terms of topography alone, and brightness variations of artifactual or unknown origin can be mentally excluded.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
HISTOCHEMISTRY, THEORETICAL AND APPLIED
Lendrum, A. C. (1969) · Journal of Clinical Pathology · doi:10.1136/jcp.22.5.625-a · Cited by 1,631
ANDERSON, T. F. (1951) · Transactions of the New York Academy of Sciences · doi:10.1111/j.2164-0947.1951.tb01007.x · Cited by 1,482
Bloom, F. E., & Aghajanian, G. K. (1968) · Journal of Ultrastructure Research · doi:10.1016/s0022-5320(68)90027-0 · Cited by 365
Principles of Biological Microtechnique
Pearse, A. G. E. (1959) · Journal of Clinical Pathology · doi:10.1136/jcp.12.2.193-c · Cited by 330
Surface Ultramicroscopy of Human Blood Cells
Clarke, J. A., & Salsbury, A. J. (1967) · Nature · doi:10.1038/215402a0 · Cited by 57
Scanning electron microscopy of sectioned tissue.
Lw, M., Pease, R. F. W., & Tl, H. (1967) · PubMed · Cited by 51
Cited by
Nation, J. L. (1983) · Stain Technology · doi:10.3109/10520298309066811 · Cited by 771
Scanning electron microscopic investigation of human dentinal tubules
Garberoglio, R., & Brännström, M. (1976) · Archives of Oral Biology · doi:10.1016/s0003-9969(76)80003-9 · Cited by 600
Design of an artificial skin. Part III. Control of pore structure
Dagalakis, N., Flink, J., Stasikelis, P., Burke, J. F., & Yannas, I. V. (1980) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820140417 · Cited by 358
Ziegler, G. R., & Foegeding, E. A. (1990) · Advances in Food and Nutrition Research · doi:10.1016/s1043-4526(08)60008-x · Cited by 349
Metadata
- Authors
- Boyde, A., & Wood, C.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1969-12
- Volume
- 90
- Issue
- 3
- Pages
- 221-249
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W1980684984
- Cited by
- 345
- References
- 6
- FWCI
- 16.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preparation of animal tissues for surface‐scanning electron microscopy. https://app.cochat.ai/papers/10.1111/j.1365-2818.1969.tb00709.x
- The paper
- Boyde, A., & Wood, C. (1969). Preparation of animal tissues for surface‐scanning electron microscopy. Journal of Microscopy. https://doi.org/10.1111/j.1365-2818.1969.tb00709.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.