The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Discrete and continuum analysis of localised deformation in sand using X-ray μCT and volumetric digital image correlation
Open accessAbstract
The objective of this work was to observe and quantify the onset and evolution of localised deformation processes in sand with grain-scale resolution. The key element of the proposed approach is combining state-of-the-art X-ray micro tomography imaging with three-dimensional volumetric digital image correlation techniques. This allows not only the grain-scale details of a deforming sand specimen to be viewed, but also, and more importantly, the evolving three-dimensional displacement and strain fields throughout loading to be assessed. X-ray imaging and digital image correlation have been in the past applied individually to study sand deformation, but the combination of these two methods to study the kinematics of shear band formation at the grain scale is the first novel aspect of this work. Moreover, the authors have developed a completely original grain-scale volumetric digital image correlation method that permits the characterisation of the full kinematics (i.e. three-dimensional displacements and rotations) of all the individual sand grains in a specimen. The results obtained using the discrete volumetric digital image correlation confirm the importance of grain rotations associated with strain localisation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A discrete numerical model for granular assemblies
Cundall, P. A., & Strack, O. D. L. (1979) · Géotechnique · doi:10.1680/geot.1979.29.1.47 · Cited by 17,527
Cited by
Maire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
An investigation of single sand particle fracture using X-ray micro-tomography
Zhao, B., Wang, J., Coop, M. R., Viggiani, G., & JIANG, M. (2015) · Géotechnique · doi:10.1680/geot.4.p.157 · Cited by 360
Self-citation
Metadata
- Authors
- HALL, S. A., BORNERT, M., DESRUES, J., PANNIER, Y., LENOIR, N., VIGGIANI, G., & BéSUELLE, P.
- Venue
- Géotechnique
- Publisher
- Emerald
- Published
- 2010-05
- Volume
- 60
- Issue
- 5
- Pages
- 315-322
- ISSN
- 0016-8505 (ISSN-L)
- 1751-7656
- OpenAlex
- W2107566402
- Cited by
- 568
- References
- 1
- FWCI
- 80.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Discrete and continuum analysis of localised deformation in sand using X-ray μCT and volumetric digital image correlation. https://app.cochat.ai/papers/10.1680/geot.2010.60.5.315
- The paper
- HALL, S. A., BORNERT, M., DESRUES, J., PANNIER, Y., LENOIR, N., VIGGIANI, G., & BéSUELLE, P. (2010). Discrete and continuum analysis of localised deformation in sand using X-ray μCT and volumetric digital image correlation. Géotechnique. https://doi.org/10.1680/geot.2010.60.5.315
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.