Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 183

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Estimating Glomerular Filtration Rate in Kidney Transplantation: A Comparison between Serum Creatinine and Cystatin C–Based Methods

White, Christine, Akbari, Ayub, Hussain, Naser, Dinh, Laurent, Filler, Guido, Lepage, Nathalie, Knoll, Greg A. · 2005 · Journal of the American Society of Nephrology

Abstract

Accurate measurement of GFR is critical for the evaluation of new therapies and the care of renal transplant recipients. Although not accurate in renal transplantation, GFR is often estimated using creatinine-based equations. Cystatin C is a marker of GFR that seems to be more accurate than creatinine. Equations to predict GFR based on the serum cystatin C concentration have been developed, but their accuracy in transplantation is unknown. GFR was estimated using four equations (Filler, Le Bricon, Larsson, and Hoek) that are based on serum cystatin C and seven equations that are based on serum creatinine in 117 adult renal transplant recipients. GFR was measured using radiolabeled diethylenetriaminepentaacetic acid (99mTc-DTPA), and the bias, precision, and accuracy of each equation were determined. The mean (99m)Tc-DTPA GFR was 58 +/- 23 ml/min per 1.73 m(2). The cystatin C-based equations of Filler and Le Bricon had the lowest bias (-1.7 and -3.8 ml/min per 1.73 m2), greatest precision (11.4 and 11.8 ml/min per 1.73 m2), and highest accuracy (87 and 89% within 30% of measured GFR, respectively). The cystatin C equations remained accurate even when the measured GFR was >60 ml/min per 1.73 m2. The creatinine-based equations were not as accurate, with only 53 to 80% of estimates within 30% of measured GFR. Cystatin C-based equations are more accurate at predicting GFR in renal transplant recipients than traditional creatinine-based equations. Further prospective studies with repetitive measurement of cystatin C are needed to determine whether cystatin C-based estimates of GFR will be sufficiently accurate to monitor long-term allograft function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1681/asn.2005050512

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 183

Metadata

Authors
White, C., Akbari, A., Hussain, N., Dinh, L., Filler, G., Lepage, N., & Knoll, G. A.
Venue
Journal of the American Society of Nephrology
Published
2005-12
Volume
16
Issue
12
Pages
3763-3770
ISSN
1046-6673 (ISSN-L)
OpenAlex
W2168933439
Cited by
183
References
3
FWCI
10.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimating Glomerular Filtration Rate in Kidney Transplantation: A Comparison between Serum Creatinine and Cystatin C–Based Methods. https://app.cochat.ai/papers/10.1681/asn.2005050512
The paper
White, C., Akbari, A., Hussain, N., Dinh, L., Filler, G., Lepage, N., & Knoll, G. A. (2005). Estimating Glomerular Filtration Rate in Kidney Transplantation: A Comparison between Serum Creatinine and Cystatin C–Based Methods. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.2005050512

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.