Ferric Gluconate Reduces Epoetin Requirements in Hemodialysis Patients with Elevated Ferritin
Open accessAbstract
The Dialysis Patients Response to IV Iron with Elevated Ferritin (DRIVE) study demonstrated the efficacy of intravenous ferric gluconate to improve hemoglobin levels in anemic hemodialysis patients who were receiving adequate epoetin doses and who had ferritin levels between 500 and 1200 ng/ml and transferrin saturation (TSAT) < or = 25%. The DRIVE-II study reported here was a 6-wk observational extension designed to investigate how ferric gluconate impacted epoetin dosage after DRIVE. During DRIVE-II, treating nephrologists and anemia managers adjusted doses of epoetin and intravenous iron as clinically indicated. By the end of observation, patients in the ferric gluconate group required significantly less epoetin than their DRIVE dose (mean change of -7527 +/- 18,021 IU/wk, P = 0.003), whereas the epoetin dose essentially did not change for patients in the control group (mean change of 649 +/- 19,987 IU/wk, P = 0.809). Mean hemoglobin, TSAT, and serum ferritin levels remained higher in the ferric gluconate group than in the control group (P = 0.062, P < 0.001, and P = 0.014, respectively). Over the entire 12-wk study period (DRIVE plus DRIVE-II), the control group experienced significantly more serious adverse events than the ferric gluconate group (incidence rate ratio = 1.73, P = 0.041). In conclusion, ferric gluconate maintains hemoglobin and allows lower epoetin doses in anemic hemodialysis patients with low TSAT and ferritin levels up to 1200 ng/ml.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Correction of anemia with epoetin alfa in chronic kidney disease
Singh, A. K., Szczech, L., Tang, K. L., Barnhart, H., Sapp, S., Wolfson, M., & Reddan, D. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa065485 · Cited by 2,762
Cited by
Macdougall, I. C., Bircher, A. J., Eckardt, K.-U., Obrador, G. T., Pollock, C. A., Stenvinkel, P., Swinkels, D. W., Wanner, C., Weiss, G., Chertow, G. M., et al. (2016) · Kidney International · doi:10.1016/j.kint.2015.10.002 · Cited by 482
Self-citationLocatelli, F., Bárány, P., Covic, A., De Francisco, A., Del Vecchio, L., Goldsmith, D., Hörl, W., London, G., Vanholder, R., Van Biesen, W., et al. (2013) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gft033 · Cited by 471
Iron Sequestration and Anemia of Inflammation
Ganz, T., & Nemeth, E. (2009) · Seminars in Hematology · doi:10.1053/j.seminhematol.2009.06.001 · Cited by 361
Iron Deficiency in Chronic Kidney Disease: Updates on Pathophysiology, Diagnosis, and Treatment
Batchelor, E. K., Kapitsinou, P., Pergola, P. E., Kovesdy, C. P., & Jalal, D. I. (2020) · Journal of the American Society of Nephrology · doi:10.1681/asn.2019020213 · Cited by 334
Clinical Use of Intravenous Iron: Administration, Efficacy, and Safety
Auerbach, M., & Ballard, H. (2010) · Hematology · doi:10.1182/asheducation-2010.1.338 · Cited by 310
Metadata
- Authors
- Kapoian, T., O'Mara, N. B., Singh, A. K., Moran, J., Rizkala, A. R., Geronemus, R., Kopelman, R. C., Dahl, N. V., & Coyne, D. W.
- Venue
- Journal of the American Society of Nephrology
- Published
- 2008-02
- Volume
- 19
- Issue
- 2
- Pages
- 372-379
- ISSN
- 1046-6673 (ISSN-L)
- OpenAlex
- W2110588229
- Cited by
- 181
- References
- 1
- FWCI
- 12.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ferric Gluconate Reduces Epoetin Requirements in Hemodialysis Patients with Elevated Ferritin. https://app.cochat.ai/papers/10.1681/asn.2007050606
- The paper
- Kapoian, T., O'Mara, N. B., Singh, A. K., Moran, J., Rizkala, A. R., Geronemus, R., Kopelman, R. C., Dahl, N. V., & Coyne, D. W. (2008). Ferric Gluconate Reduces Epoetin Requirements in Hemodialysis Patients with Elevated Ferritin. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.2007050606
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.