CoChat

Infection Risk with Bolus versus Maintenance Iron Supplementation in Hemodialysis Patients

Open access
Brookhart, M. Alan, Freburger, Janet K., Ellis, Alan R., Wang, Lily, Winkelmayer, Wolfgang C., Kshirsagar, Abhijit V. · 2013 · Journal of the American Society of Nephrology
Cited by 155

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Intravenous iron may promote bacterial growth and impair host defense, but the risk of infection associated with iron supplementation is not well defined. We conducted a retrospective cohort study of hemodialysis patients to compare the safety of bolus dosing, which provides a large amount of iron over a short period of time on an as-needed basis, with maintenance dosing, which provides smaller amounts of iron on a regular schedule to maintain iron repletion. Using clinical data from 117,050 patients of a large US dialysis provider merged with data from Medicare's ESRD program, we estimated the effects of iron dosing patterns during repeated 1-month exposure periods on risks of mortality and infection-related hospitalizations during the subsequent 3 months. Of 776,203 exposure/follow-up pairs, 13% involved bolus dosing, 49% involved maintenance dosing, and 38% did not include exposure to iron. Multivariable additive risk models found that patients receiving bolus versus maintenance iron were at increased risk of infection-related hospitalization (risk difference [RD], 25 additional events/1000 patient-years; 95% confidence interval [CI], 16 to 33) during follow-up. Risks were largest among patients with a catheter (RD, 73 events/1000 patient-years; 95% CI, 48 to 99) and a recent infection (RD, 57 events/1000 patient-years; 95% CI, 19 to 99). We also observed an association between bolus dosing and infection-related mortality. Compared with no iron, maintenance dosing did not associate with increased risks for adverse outcomes. These results suggest that maintenance iron supplementation may result in fewer infections than bolus dosing, particularly among patients with a catheter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1681/asn.2012121164

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 155

Metadata

Authors
Brookhart, M. A., Freburger, J. K., Ellis, A. R., Wang, L., Winkelmayer, W. C., & Kshirsagar, A. V.
Venue
Journal of the American Society of Nephrology
Published
2013-07
Volume
24
Issue
7
Pages
1151-1158
ISSN
1046-6673 (ISSN-L)
OpenAlex
W2158623958
Cited by
155
References
4
FWCI
15.36
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Infection Risk with Bolus versus Maintenance Iron Supplementation in Hemodialysis Patients. https://app.cochat.ai/papers/10.1681/asn.2012121164
The paper
Brookhart, M. A., Freburger, J. K., Ellis, A. R., Wang, L., Winkelmayer, W. C., & Kshirsagar, A. V. (2013). Infection Risk with Bolus versus Maintenance Iron Supplementation in Hemodialysis Patients. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.2012121164

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.