CoChat

Body Composition in Renal Transplant Patients: Bioimpedance Analysis Compared to Isotope Dilution, Dual Energy X-Ray Absorptiometry, and Anthropometry

Open access
VAN DEN HAM, EUGÉNIE C.H., KOOMAN, JEROEN P., CHRISTIAANS, MAARTEN H.L., NIEMAN, FRED H.M., VAN KREEL, BERNHARD K., HEIDENDAL, GUIDO A.K., VAN HOOFF, JOHANNES P. · 1999 · Journal of the American Society of Nephrology
Cited by 95

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

: Whether multifrequency bioelectrical impedance analysis (MF-BIA), a relatively new method for measuring body composition, is also applicable for accurate body composition measurements in renal transplant (RTx) patients is not known. Therefore, the use of MF-BIA is validated in 77 RTx patients with a stable renal function at least 2 yr posttransplantation. MF-BIA is compared to isotope dilution techniques for measurement of body water compartments, and to dual energy x-ray absorptiometry (DEXA) and anthropometry for measurement of fat and fat free mass. Finally, DEXA and anthropometry are compared to each other. Method agreement is assessed by intraclass correlation coefficients (ICC) and plotted by Bland and Altman analysis. MF-BIA significantly underestimates total body water (TBW, 0.7 ± 2.1 L) and overestimates the extracellular water (ECW, 3.3 ± 1.8 L) compared to isotope dilution; the ICC between both techniques is 0.943 for TBW and 0.846 for ECW. The percentage body fat (BF) measured by MF-BIA is significantly higher than both BF measured by DEXA (3.4 ± 4.7%) or by anthropometry (5.5 ± 5.2%). The ICC between MF-BIA and DEXA is 0.887 and between MF-BIA and anthropometry 0.856. BF measured by DEXA is significantly higher than BF measured by anthropometry (2.1 ± 4.4%); their ICC is 0.913. In conclusion, MF-BIA seems to be suitable for measurement of TBW in RTx patients; however, method agreement between isotope dilution and MF-BIA for the measurement of ECW is not satisfactory. In the assessment of fat and fat free mass, the reliability of MF-BIA appears to be questionable. Method agreement between DEXA and anthropometry seems to be slightly better.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1681/asn.v1051067

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 95

Metadata

Authors
VAN DEN HAM, E. C. H., KOOMAN, J. P., CHRISTIAANS, M. H. L., NIEMAN, F. H. M., VAN KREEL, B. K., HEIDENDAL, G. A. K., & VAN HOOFF, J. P.
Venue
Journal of the American Society of Nephrology
Published
1999-05
Volume
10
Issue
5
Pages
1067-1079
ISSN
1046-6673 (ISSN-L)
OpenAlex
W2171264714
Cited by
95
References
5
FWCI
2.42
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.