The DOI matches its Crossref record.
Biocompatibility of hemodialysis membranes.
Abstract
Exposure of blood to hemodialysis membranes results in numerous interactions between the blood elements and the membrane. Transformation and adsorption of plasma proteins (such as complement) and activation of blood cells (such as neutrophils and monocytes) have been studied most extensively by nephrologists in recent years. There is no consensus on the definition of biocompatibility for dialyzer membranes. An operational definition of biocompatibility is the lack of any perturbation of blood constituents. According to this "inert surface" definition, a membrane (for example, one that adsorbs beta 2-microglobulin) can be considered as bioincompatible and yet desirable. Because of the multitude of blood-membrane interactions that may occur during hemodialysis, multiple criteria for biocompatibility needs to be applied in the classification of membranes. A certain bioincompatible phenomenon can be further classified as beneficial or deleterious depending on its biological effects as well as its acute and chronic impacts on the dialysis patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thadhani, R., Pascual, M., & Bonventre, J. V. (1996) · New England Journal of Medicine · doi:10.1056/nejm199605303342207 · Cited by 1,417
The elephant in uremia: Oxidant stress as a unifying concept of cardiovascular disease in uremia
Himmelfarb, J., Stenvinkel, P., Ikizler, T. A., & Hakim, R. M. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00600.x · Cited by 1,179
Neutrophils: Molecules, Functions and Pathophysiological Aspects
Witko-Sarsat, V., Rieu, P., Descamps-Latscha, B., Lesavre, P., & Halbwachs-Mecarelli, L. (2000) · Laboratory Investigation · doi:10.1038/labinvest.3780067 · Cited by 1,135
Functional cardiac cell constructs on cellulose-based scaffolding
Entcheva, E., Bien, H., Yin, L., Chung, C.-Y., Farrell, M., & Kostov, Y. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.024 · Cited by 327
Plasma protein thiol oxidation and carbonyl formation in chronic renal failure
Himmelfarb, J., McMonagle, E., & McMenamin, E. (2000) · Kidney International · doi:10.1046/j.1523-1755.2000.00443.x · Cited by 267
Metadata
- Authors
- Cheung, A. K.
- Venue
- Journal of the American Society of Nephrology
- Published
- 1990-08
- Volume
- 1
- Issue
- 2
- Pages
- 150-161
- ISSN
- 1046-6673 (ISSN-L)
- OpenAlex
- W2113313914
- Cited by
- 215
- References
- 0
- FWCI
- 6.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biocompatibility of hemodialysis membranes. https://app.cochat.ai/papers/10.1681/asn.v12150
- The paper
- Cheung, A. K. (1990). Biocompatibility of hemodialysis membranes. Journal of the American Society of Nephrology. https://doi.org/10.1681/asn.v12150
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.