Cited by 257Body Composition Measurement TechniquesDialysis and Renal Disease ManagementClinical Nutrition and Gastroenterology

Nutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients.

Chertow, G M, Lowrie, E G, Wilmore, D W, Gonzalez, J, Lew, N L, Ling, J, Leboff, M S, Gottlieb, M N +2 more·1995·Journal of the American Society of Nephrology

Abstract

Protein energy malnutrition is common among persons with ESRD and contributes substantially to morbidity and mortality. The usual methods of nutritional assessment, such as anthropometry, can be misleading because of altered tissue hydration. Bioelectrical impedance analysis (BIA) has been recommended by some as a practical nutritional assessment tool but has not been validated in patients with ESRD. Thirty-three stable patients on maintenance hemodialysis were evaluated in an ambulatory clinical research center with simultaneous BIA, dual-energy x-ray absorptiometry, and deuterium oxide (D2O) and sodium bromide (NaBr) isotope dilution studies. Standard determinations of total body water (TBW) and body cell mass (BCM) were obtained and compared with values estimated by BIA. Two separate outpatient BIA measurements were also obtained approximately 2 wk before and after the clinical research center evaluation. BCM estimated by BIA was directly correlated (r = 0.92, P < 0.0001) with BCM determined by DEXA and NaBr. TBW estimated by BIA was directly correlated (r = 0.96, P < 0.0001) with TBW determined by deuterium oxide dilution. The reactance to resistance ratio (Xc/R) derived from BIA was inversely correlated (r = -0.73, P < 0.0001) with the extracellular water/TBW ratio determined by NaBr/D2O. Bland-Altman analyses showed that for TBW, BIA was in excellent agreement with D2O dilution. BCM was modestly underestimated by BIA compared with the dual-energy x-ray absorptiometry/NaBr standard and was adjusted by linear regression. The coefficients of variation on repeated BIA measurements were below 4%, demonstrating test-retest reliability. BIA is a valid and reliable method of nutritional assessment in maintenance hemodialysis patients.

Integrity signals

Registry

Crossref · 10.1681/asn.v6175

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Chertow, G. M., Lowrie, E. G., Wilmore, D. W., Gonzalez, J., Lew, N. L., Ling, J., Leboff, M. S., Gottlieb, M. N., Huang, W., & Zebrowski, B.
Affiliations
Brigham and Women's Hospital (US)
Venue
Journal of the American Society of Nephrology
Published
1995-07
Volume
6
Issue
1
Pages
75-81
ISSN
1046-6673 (ISSN-L)
OpenAlex
W2131315231
Cited by
257
References
1
Citations by year
2026: 1 · 2025: 3 · 2024: 1 · 2023: 7 · 2022: 7 · 2021: 9 · 2020: 7 · 2019: 7 · 2018: 9 · 2017: 15 · 2016: 4 · 2015: 8 · 2014: 12 · 2013: 10 · 2012: 9
FWCI
6.43
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of the American Society of Nephrology (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Center for Research Resources (M01RR002635, MO1 RR 02635)
Topics
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
  • Health Sciences › Medicine › Nephrology › Dialysis and Renal Disease Management
  • Health Sciences › Nursing › Nutrition and Dietetics › Clinical Nutrition and Gastroenterology
Keywords
bioelectrical impedance analysis, nutritional assessment, maintenance hemodialysis, end-stage renal disease, protein-energy malnutrition, body cell mass, total body water, extracellular water, isotope dilution, dual-energy X-ray absorptiometry, test-retest reliability
MeSH terms
Adult, Aged, Body Composition, Body Water, Bromides, Evaluation Studies as Topic, Female, Renal Dialysis, Humans, Kidney Failure, Chronic, Male, Middle Aged, Protein-Energy Malnutrition, Time Factors, Reproducibility of Results, Absorptiometry, Photon, Nutrition Assessment, Electric Impedance, Deuterium Oxide, Sodium Compounds

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review