CoChat

Predialysis systolic blood pressure correlates strongly with mean 24-hour systolic blood pressure and left ventricular mass in stable hemodialysis patients.

Conion, P J, Walshe, J J, Heinle, S K, Minda, S, Krucoff, M, Schwab, S J · 1996 · Journal of the American Society of Nephrology
Cited by 102

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

This study used a 24-h ambulatory blood pressure (ABP) monitor to study the relationship between dialysis room-measured blood pressures (BP) and mean 24-h systolic and diastolic ambulatory BP (SABP and DABP) with left ventricular mass (LV) in a group of 35 stable hemodialysis patients. Predialysis and postdialysis systolic and diastolic blood pressure data were collected for the 12 dialysis treatments before the wearing of the ABP device, and the means of these values are reported. All patients were maintained on the same antihypertensive medications for 3 months before the study and had a stable hematocrit value of 30 +/- 3% during this time period. There was no difference detected between daytime and nighttime ABP. SABP was a mean of 4.7 mm Hg below predialysis systolic BP (P = 0.004) and DABP was a mean of 3.7 mm Hg below predialysis diastolic BP. There was a strong correlation between SABP and predialysis systolic BP (r = 0.67, P = 0.0001); however, postdialysis diastolic BP correlated better with DABP than did predialysis diastolic BP. In addition, LV mass correlated with SABP (r = 0.35, P = 0.03) and predialysis systolic BP (r = 0.35, P = 0.03). There was no apparent correlation between either pre- or postdialysis diastolic BP with LV mass. It was concluded that predialysis systolic BP and postdialysis diastolic BP correlates strongly with SABP and DABP. Furthermore, predialysis systolic BP correlates with LV mass in hemodialysis patients. If the deleterious effects of hypertension in this patient population are to be avoided, it is the predialysis systolic BP that needs to be controlled: It is insufficient to be satisfied with good postdialysis BP control, if patients are hypertensive before beginning dialysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1681/asn.v7122658

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Conion, P. J., Walshe, J. J., Heinle, S. K., Minda, S., Krucoff, M., & Schwab, S. J.
Venue
Journal of the American Society of Nephrology
Published
1996-12
Volume
7
Issue
12
Pages
2658-2663
ISSN
1046-6673 (ISSN-L)
OpenAlex
W2109223762
Cited by
102
References
2
FWCI
3.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.