CoChat

Detection of anaemia from retinal fundus images via deep learning

Open access

The DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.

Abstract

Owing to the invasiveness of diagnostic tests for anaemia and the costs associated with screening for it, the condition is often undetected. Here, we show that anaemia can be detected via machine-learning algorithms trained using retinal fundus images, study participant metadata (including race or ethnicity, age, sex and blood pressure) or the combination of both data types (images and study participant metadata). In a validation dataset of 11,388 study participants from the UK Biobank, the fundus-image-only, metadata-only and combined models predicted haemoglobin concentration (in g dl-1) with mean absolute error values of 0.73 (95% confidence interval: 0.72-0.74), 0.67 (0.66-0.68) and 0.63 (0.62-0.64), respectively, and with areas under the receiver operating characteristic curve (AUC) values of 0.74 (0.71-0.76), 0.87 (0.85-0.89) and 0.88 (0.86-0.89), respectively. For 539 study participants with self-reported diabetes, the combined model predicted haemoglobin concentration with a mean absolute error of 0.73 (0.68-0.78) and anaemia an AUC of 0.89 (0.85-0.93). Automated anaemia screening on the basis of fundus images could particularly aid patients with diabetes undergoing regular retinal imaging and for whom anaemia can increase morbidity and mortality risks.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41551-019-0487-z

Cites

74 of 74 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 74 references

Research works printed but not linked: 1

  1. Sundararajan, M., Taly, A. & Yan, Q. Axiomatic attribution for deep networks. In Proc. of the 34th International Conference on Machine Learning 3319–3328 (Microtome Publishing, 2017).

Cited by

See all 259

Metadata

Authors
Mitani, A., Huang, A., Venugopalan, S., Corrado, G. S., Peng, L., Webster, D. R., Hammel, N., Liu, Y., & Varadarajan, A. V.
Affiliations
Google (United States) (US)
Corresponding author
Mitani, Akinori
Venue
Nature Biomedical Engineering
Published
2019-12-23
Volume
4
Issue
1
Pages
18-27
ISSN
2157-846X (ISSN-L)
OpenAlex
W2995850447
Cited by
230
References
72
Citations by year
2026: 25 · 2025: 32 · 2024: 38 · 2023: 41 · 2022: 37 · 2021: 32 · 2020: 23 · 2019: 1
FWCI
15.35
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Funders
Google
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
  • Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Health Research
Keywords
anemia detection, fundus images, automated screening, diabetes mellitus, UK Biobank, multimodal fusion, retinal imaging, deep learning
MeSH terms
Deep Learning, Anemia, Female, Fundus Oculi, Humans, Male, Middle Aged, Prospective Studies, Retina, ROC Curve

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of anaemia from retinal fundus images via deep learning. https://app.cochat.ai/papers/10.1038/s41551-019-0487-z
The paper
Mitani, A., Huang, A., Venugopalan, S., Corrado, G. S., Peng, L., Webster, D. R., Hammel, N., Liu, Y., & Varadarajan, A. V. (2019). Detection of anaemia from retinal fundus images via deep learning. Nature Biomedical Engineering. https://doi.org/10.1038/s41551-019-0487-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.