The DOI matches its Crossref record.
Considerations for design of future cochlear implant electrode arrays: Electrode array stiffness, size,
Open accessAbstract
The level of hearing rehabilitation enjoyed by cochlear implant (CI) recipients has increased dramatically since the introduction of these devices. This improvement is the result of continual development of these systems and the inclusion of subjects with less severe auditory pathology. Developments include advanced signal processing, higher stimulation rates, greater numbers of channels, and more efficient electrode arrays that are less likely to produce insertion damage. New directions in the application of CIs, particularly in combined acoustic and electrical stimulation, and increasing performance expectations will place greater demands on future electrode arrays. Specifically, the next generation of arrays must be reliably inserted without damage, must maintain residual acoustic function, and may need to be inserted more deeply. In this study, we measured the mechanical properties of eight clinical and prototype human CI electrode arrays and evaluated insertion trauma and insertion depth in 79 implanted cadaver temporal bones. We found that the size and shape of the array directly affect the incidence of observed trauma. Further, arrays with greater stiffness in the plane perpendicular to the plane of the cochlear spiral are less likely to cause severe trauma than arrays with similar vertical and horizontal stiffness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Self-citationAn overview of cochlear implant electrode array designs
Dhanasingh, A., & Jolly, C. (2017) · Hearing Research · doi:10.1016/j.heares.2017.10.005 · Cited by 311
The cochlear implant: historical aspects and future prospects
Eshraghi, A. A., Nazarian, R., Telischi, F. F., Rajguru, S. M., Truy, E., & Gupta, C. (2012) · The Anatomical Record · doi:10.1002/ar.22580 · Cited by 285
Organic electronics for neuroprosthetics
Airaghi Leccardi, M. J. I., & Ghezzi, D. (2020) · Healthcare Technology Letters · doi:10.1049/htl.2019.0108 · Cited by 12
Metadata
- Authors
- Rebscher, S. J.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2008-12-01
- Volume
- 45
- Issue
- 5
- Pages
- 731-748
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W2116831588
- Cited by
- 169
- References
- 0
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Considerations for design of future cochlear implant electrode arrays: Electrode array stiffness, size,. https://app.cochat.ai/papers/10.1682/jrrd.2007.08.0119
- The paper
- Rebscher, S. J. (2008). Considerations for design of future cochlear implant electrode arrays: Electrode array stiffness, size,. The Journal of Rehabilitation Research and Development. https://doi.org/10.1682/jrrd.2007.08.0119
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.