The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Review of hybrid exoskeletons to restore gait following spinal cord injury
Abstract
Different approaches are available to compensate gait in persons with spinal cord injury, including passive orthoses, functional electrical stimulation (FES), and robotic exoskeletons. However, several drawbacks arise from each specific approach. Orthotic gait is energy-demanding for the user and functionally ineffective. FES uses the muscles as natural actuators to generate gait, providing not only functional but also psychological benefits to the users. However, disadvantages are also related to the early appearance of muscle fatigue and the control of joint trajectories. Robotic exoskeletons that provide joint moment compensation or substitution to the body during walking have been developed in recent years. Significant advances have been achieved, but the technology itself is not mature yet because of many limitations related to both physical and cognitive interaction as well as portability and energy-management issues. Meanwhile, the combination of FES technology and exoskeletons has emerged as a promising approach to both gait compensation and rehabilitation, bringing together technologies, methods, and rehabilitation principles that can overcome the drawbacks of each individual approach. This article presents an overview of hybrid lower-limb exoskeletons, related technologies, and advances in actuation and control systems. Also, we highlight the functional assessment of individuals with spinal cord injury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical use of the odstock dropped foot stimulator: Its effect on the speed and effort of walking
Taylor, P. N., Burridge, J. H., Dunkerley, A. L., Wood, D. E., Norton, J. A., Singleton, C., & Swain, I. D. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90333-7 · Cited by 275
Graupe, D., & Kohn, K. (1997) · Neurological Research · doi:10.1080/01616412.1997.11740820 · Cited by 41
Cited by
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
Lower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 455
Self-citationOpportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Metadata
- Authors
- del-Ama, A. J., Koutsou, A. D., Moreno, J. C., de-los-Reyes, A., Gil-Agudo, N., & Pons, J. L.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2012
- Volume
- 49
- Issue
- 4
- Pages
- 497
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W2147175557
- Cited by
- 174
- References
- 2
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review of hybrid exoskeletons to restore gait following spinal cord injury. https://app.cochat.ai/papers/10.1682/jrrd.2011.03.0043
- The paper
- del-Ama, A. J., Koutsou, A. D., Moreno, J. C., de-los-Reyes, A., Gil-Agudo, N., & Pons, J. L. (2012). Review of hybrid exoskeletons to restore gait following spinal cord injury. The Journal of Rehabilitation Research and Development. https://doi.org/10.1682/jrrd.2011.03.0043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.