Test No. 114: Viscosity of Liquids

OECD·2012·OECD Guidelines for the Testing of Chemicals, Section 1

Abstract

This Test Guideline describes methods to measure the viscosity of liquids. Most of the methods listed are appropriate for the investigation of Newtonian liquids. The measurement of non-Newtonian liquids is possible with the rotational viscometer. Viscosity measurements are carried out according to five methods: the capillary viscometer, the flow cup, the rotational viscometer, the rolling ball viscometer and the drawing ball viscometer. Each determination of viscosity should be made at a temperature of 20°C and at 40°C. At least two determinations should be made at each temperature. The viscosity measurement is to be carried out according to the standards in the case of capillary and forced ball viscometers. In the case of rotational viscometers, the specification of a viscosity is appropriate only for Newtonian fluids. For non- Newtonian fluids, the results obtained are preferred in table or graph form, preferably in the order of increasing shear rate.

Overview

Integrity signals

Registry

Crossref · 10.1787/9789264185180-en

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cited by

Sorted by citations

Metadata

Authors
OECD
Venue
OECD Guidelines for the Testing of Chemicals, Section 1
Publisher
OECD
Published
2012-10-02
ISSN
2074-5753
Cited by
0
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review