Advanced cryogenic insulation systems
Open accessAbstract
New materials in recent decades have enabled advances in thermal insulation systems for storage and transfer of cryogens. To preserve the and achieve efficient cryogenic systems, a combination of materials, testing, and engineering is required. The total heat leak into any cryogenic assembly is comprised of three main parts: 1) heat leak through the insulation, 2) heat leak through the support structures, and 3) heat leak attributed to piping penetrations and feedthroughs (and their negative effects on the insulation). This cold triangle approach provides a basis for evaluating performance benefits of new materials and analyzing the cost effectiveness in overall system design. Provided are thermophysical data for aerogels, aerogel composites, novel multilayered composites, and glass bubbles for standard test conditions of 293 K and 78 K under conditions from high vacuum to ambient pressure. Examples of cryogenic storage tanks show the relative importance of both insulation and structural materials for achieving designs of highest energy efficiency.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The total heat load transmitted to the inner vessel is determined by the combination of evacuated insulation, structural supports, and piping penetrations.
“The three key ingredients of thermal performance for an LH2 tank design are: evacuated insulation; structural supports; and piping penetrations.The total heat load being transmitted to the inner vessel is determined by the combination of these three interdependent factors [7].”
From Energy efficient large-scale storage of liquid hydrogen (2022) · cites this paper as [7]
Cited by
Sorted by citations
Effective thermal conductivity of insulation materials for cryogenic LH2 storage tanks: A review
Ratnakar, R. R., Sun, Z., & Balakotaiah, V. (2023) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2022.11.130 · Cited by 73 · see citing works
Energy efficient large-scale storage of liquid hydrogen
Fesmire, J., Swanger, A., Jacobson, J., & Notardonato, W. (2022) · IOP Conference Series: Materials Science and Engineering · doi:10.1088/1757-899x/1240/1/012088 · Cited by 59 · see citing works
“The total heat load being transmitted to the inner vessel is determined by the combination of these three interdependent factors [7].”
BackgroundSelf-citation
- Authors
- J., F., & A., S.
- Venue
- International Institute of Refrigeration (IIR)
- Publisher
- International Institute of Refrigeration (IIR)
- Published
- 2019
- OpenAlex
- W3029052931
- Cited by
- 8
- References
- 0
- Citations by year
- 2025: 1 · 2024: 3 · 2023: 2 · 2022: 2
- FWCI
- 2.95
- Type
- conference paper
- Language
- en
- Open access
- green
- doi.org
- Locations
- Institut International du Froid
- Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Spacecraft and Cryogenic Technologies
- Physical Sciences › Chemistry › Spectroscopy › Aerogels and thermal insulation
- Physical Sciences › Engineering › Biomedical Engineering › Superconducting Materials and Applications
- Keywords
- cryogenic insulation, heat leakage, cryogenic storage tanks, cryogenic piping, aerogels, composite aerogels, multilayer composites, hollow glass microspheres, thermophysical properties, structural materials, energy efficiency
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review