Adherence to the NASPE Guideline for Amiodarone Monitoring at a Medical University

Open access
Bickford, Courtney L., Spencer, Anne P.·2006·Journal of Managed Care Pharmacy

Abstract

OBJECTIVE: Amiodarone is an effective antiarrhythmic, but the clinical usefulness of this agent is complicated by its extensive side-effect profile, which necessitates careful patient selection and frequent monitoring. The purpose of this study was to quantify adherence to published recommendations for baseline monitoring when initiating inpatient amiodarone therapy at a university teaching hospital and determine whether appropriate serial monitoring of chronic amiodarone therapy (e 6 months) is occurring in the outpatient setting. METHODS: A retrospective review of electronic medical records was conducted for inpatients at the Medical University of South Carolina (MUSC) who received amiodarone between November 1, 2003, and March 31, 2004, and for a subset of outpatients who had received amiodarone therapy for at least 6 months. Their medical records were reviewed for demographic data; reason for, date of initiation of, and duration of amiodarone therapy; and the occurrence of laboratory and diagnostic tests. The amiodarone guideline from the North American Society of Pacing and Electrophysiology (NASPE) was used as the measure of appropriate monitoring for baseline and follow-up chest x-rays (CXRs), liver function tests (LFTs), thyroid function tests (TFTs), and pulmonary function tests (PFTs). RESULTS: Over the 5-month period from November 1, 2003, through March 31, 2004, 277 adult patients received oral amiodarone as inpatients at MUSC. Of these, 45 patients (16%) were initiated on chronic amiodarone therapy during their hospital admission. Baseline assessments of CXRs, LFTs, and TFTs occurred in 82% to 87% of these patients. Baseline assessment of PFTs occurred in 24% of patients, and 55% of these assessments included a diffusion capacity (DLCO). Overall, only 5 (11%) of the 45 patients initiated on amiodarone received all recommended monitoring tests. Twenty patients with available outpatient records in the MUSC system were identified as receiving chronic amiodarone therapy. Baseline assessments of LFTs, TFTs, and CXRs occurred in approximately 75% to 95% of these patients; baseline assessment of PFTs occurred in d 30%, and 83% of these included a DLCO. Chronic monitoring at recommended time intervals for LFTs and TFTs occurred in 35% and 20% of patients, respectively, whereas annual CXRs were performed appropriately in 50% of patients. CONCLUSION: Our data suggest that opportunities exist for improved monitoring of amiodarone therapy according to the NASPE guidelines and provide support for the development of a protocol to ensure continuous amiodarone monitoring.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.18553/jmcp.2006.12.3.254

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Mason JW. Amiodarone. N Engl J Med. 1987;316(8):455-66.

Cited by

Sorted by citations

Authors
Bickford, C. L., & Spencer, A. P.
Affiliations
The University of Texas MD Anderson Cancer Center (US)
Venue
Journal of Managed Care Pharmacy
Published
2006-04
Volume
12
Issue
3
Pages
254-259
ISSN
  • 1083-4087 (ISSN-L)
  • 1944-706X
OpenAlex
W2143486799
Cited by
25
References
13
Citations by year
2020: 3 · 2019: 1 · 2017: 4 · 2016: 3 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 2
FWCI
1.19
Type
journal article
Language
en
Open access
Locations
  • Journal of Managed Care Pharmacy (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Pharmacovigilance and Adverse Drug Reactions
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
Keywords
amiodarone, guideline adherence, drug monitoring, antiarrhythmic drugs, liver function tests, thyroid function tests, chest radiography, pulmonary function tests, diffusing capacity for carbon monoxide, outpatient follow-up, adverse drug reactions, medical records review, electronic health records
MeSH terms
Academic Medical Centers, Adult, Aged, Aged, 80 and over, Amiodarone, Anti-Arrhythmia Agents, Drug Labeling, Female, Humans, Liver Function Tests, Male, Middle Aged, Respiratory Function Tests, Societies, Scientific, South Carolina, Drug Monitoring, Guideline Adherence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review