Effect of V-Go Versus Multiple Daily Injections on Glycemic Control, Insulin Use, and Diabetes Medication Costs Among Individuals with Type 2 Diabetes Mellitus
The DOI matches its Crossref record.
Abstract
BACKGROUND: Coping with discomfort and the uncertainties of daily adjustments are prominent challenges confronting individuals with type 2 diabetes mellitus (T2DM) who require multiple daily injections (MDI) of insulin. For this growing population, wearable, disposable devices capable of delivering consistent and sustained doses of basal-bolus therapy may help to alleviate concerns and improve outcomes. However, studies on the comparative effectiveness of new, innovative delivery systems versus MDI on insulin requirements, glycemic control, and health care costs are sparse. OBJECTIVE: To examine glycemic control, insulin use, and diabetes medication costs for users of the V-Go Wearable Insulin Delivery device compared with MDI insulin therapy among individuals with T2DM in a commercially insured population in the United States. METHODS: This retrospective cohort study queried administrative claims data from the HealthCore Integrated Research Database from July 1, 2011, through July 31, 2017. Cohorts included individuals with T2DM aged 21-80 years either newly initiating V-Go or using MDI for basal/bolus insulin. The date of earliest claim for V-Go prescription fill or for bolus insulin was defined as the index date, depending on the cohort. Previous insulin therapy was required in both cohorts. Baseline hemoglobin A1c (A1c) values were identified during the 6 months before and 15 days after the index date; results closest to 12 months after the index date were selected as follow-up. Insulin use and diabetes medication cost data were examined during the 6 months baseline and the second half of the 1-year follow-up. V-Go and MDI users were 1:1 matched on baseline insulin exposure, A1c level, and other characteristics of interest. Univariate and multivariate tests were used to compare follow-up outcomes. RESULTS: < 0.001; -21% vs. +4%), compared with MDI users, during the last 6 months of follow-up. CONCLUSIONS: This study was the first to evaluate clinical and economic outcomes associated with the use of V-Go for up to a 1-year follow-up period. Relative to MDI users, V-Go users had similar glycemic control but lower insulin use and lower diabetes medication costs during follow-up. V-Go therapy may provide an opportunity to improve quality measures more cost-effectively in people with T2DM who require basal-bolus therapy. DISCLOSURES: This study was funded by Valeritas. Nguyen is an employee of Valeritas. Zhou, Grabner, Barron, and Quimbo are employees of HealthCore, which received funding for this study from Valeritas. Raval was an employee of HealthCore at the time the study was conducted. Partial findings from this study were presented at the International Society of Pharmacoeconomics and Outcomes Research 23rd Annual International Meeting; May 19-23, 2018; Baltimore, MD; and the 54th European Association for the Study of Diabetes Annual Meeting; October 1-5, 2018; Berlin, Germany.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202
“Another pump option in people with type 2 diabetes is a disposable patchlike device, which provides a continuous, subcutaneous infusion of rapid-acting insulin (basal) as well as 2-unit increments of bolus insulin at the press of a button (153,155,158).”
Background
Metadata
- Authors
- Raval, A. D., Nguyen, M. H., Zhou, S., Grabner, M., Barron, J., & Quimbo, R.
- Venue
- Journal of Managed Care & Specialty Pharmacy
- Publisher
- Academy of Managed Care Pharmacy
- Published
- 2019-07-05
- Pages
- 1-14
- ISSN
- 2376-0540 (ISSN-L)
- 2376-1032
- OpenAlex
- W4234075742
- Cited by
- 8
- References
- 0
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of V-Go Versus Multiple Daily Injections on Glycemic Control, Insulin Use, and Diabetes Medication Costs Among Individuals with Type 2 Diabetes Mellitus. https://app.cochat.ai/papers/10.18553/jmcp.2019.18438
- The paper
- Raval, A. D., Nguyen, M. H., Zhou, S., Grabner, M., Barron, J., & Quimbo, R. (2019). Effect of V-Go Versus Multiple Daily Injections on Glycemic Control, Insulin Use, and Diabetes Medication Costs Among Individuals with Type 2 Diabetes Mellitus. Journal of Managed Care & Specialty Pharmacy. https://doi.org/10.18553/jmcp.2019.18438
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.