Oxygen intake efficiency slope: a new index of cardiorespiratory functional reserve derived from the relationship between oxygen consumption and minute ventilation during incremental exercise.
Open accessThe DOI matches its OpenAlex record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We investigated the usefulness of the oxygen intake efficiency slope (OIES) as a submaximal measure of cardiorespiratory functional reserve. OIES was derived from the relationship between oxygen consumption (VO2; ml/min) and minute ventilation (VE; l/min) during incremental exercise, which was determined by the following equation: VO2 = a logVE + b, where "a" represents OIES, which shows the effectiveness of ventilation. Maximal oxygen consumption (VO2max) is effort-dependent. There is no standard submaximal measurement of cardiorespiratory reserve that provides generally acceptable results. Exercise tests were performed by 17 normal volunteers on an ergometer using a symptom-limited Ramp protocol. Expired gas was continuously analyzed. OIES was calculated using the first 75%, 90%, and 100% of exercise data. We also determined the following submaximal parameters: the ventilatory anaerobic threshold (VAT), the slope of the minute ventilation-carbon dioxide production relationship (VE-VCO2 slope), and the extrapolated maximal oxygen consumption (EMOC). We analyzed the relationship between OIES, other submaximal parameters and VO2max, and examined the effects of submaximal exercise on OIES. The correlation coefficient of the logarithmic curve-fitting model was 0.991 +/- 0.006. OIES and VO2max were significantly correlated (r = 0.966, p < 0.0001). The correlation between OIES and VO2max was stronger than the correlation between VO2max and VAT, the VE-VCO2 slope and EMOC. OIES values for 100% and 90% of exercise were identical; OIES for 75% of exercise was slightly lower (3%). Our results suggested that OIES may provide an objective, effort-independent estimation of cardiorespiratory functional reserve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Cited by
Balady, G. J., Arena, R., Sietsema, K., Myers, J., Coke, L., Fletcher, G. F., Forman, D., Franklin, B., Guazzi, M., Gulati, M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181e52e69 · Cited by 1,964
Guazzi, M., Adams, V., Conraads, V., Halle, M., Mezzani, A., Vanhees, L., Arena, R., Fletcher, G. F., Forman, D. E., Kitzman, D. W., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31826fb946 · Cited by 822
Guazzi, M., Arena, R., Halle, M., Piepoli, M. F., Myers, J., & Lavie, C. J. (2016) · Circulation · doi:10.1161/cir.0000000000000406 · Cited by 457
Writing Committee, EACPR:, Guazzi, M., Adams, V., Conraads, V., Halle, M., Mezzani, A., Vanhees, L., AHA:, Arena, R., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs221 · Cited by 318
Guazzi, M., Arena, R., Halle, M., Piepoli, M. F., Myers, J., & Lavie, C. J. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehw180 · Cited by 266
Metadata
- Authors
- Baba, R., Nagashima, M., Goto, M., Nagano, Y., Yokota, M., Tauchi, N., & Nishibata, K.
- Venue
- PubMed
- Publisher
- National Institutes of Health
- Published
- 1996-03-01
- Volume
- 59
- Issue
- 1-2
- Pages
- 55-62
- OpenAlex
- W1491048079
- Cited by
- 46
- References
- 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen intake efficiency slope: a new index of cardiorespiratory functional reserve derived from the relationship between oxygen consumption and minute ventilation during incremental exercise. https://app.cochat.ai/papers/10.18999/nagjms.59.1-2.55
- The paper
- Baba, R., Nagashima, M., Goto, M., Nagano, Y., Yokota, M., Tauchi, N., & Nishibata, K. (1996). Oxygen intake efficiency slope: a new index of cardiorespiratory functional reserve derived from the relationship between oxygen consumption and minute ventilation during incremental exercise. PubMed. https://doi.org/10.18999/nagjms.59.1-2.55
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.