Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 678

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Crestal Bone Changes Around Titanium Implants. A Radiographic Evaluation of Unloaded Nonsubmerged and Submerged Implants in the Canine Mandible

Open access
Hermann, Joachim S., Cochran, David L., Nummikoski, Pirkka V., Buser, Daniel·1997·Journal of Periodontology

Abstract

C urrent implant placement utilizes both nonsubmerged and submerged techniques. However, the implications of the location of a rough/smooth implant interface as well as the location of a microgap between implant and abutment on crestal bone changes are not well understood. The purpose of this study was to radiographically evaluate crestal bone changes around unloaded nonsubmerged and submerged titanium implants in a side‐by‐side comparison. Fifty‐nine (59) implants were placed at different levels to the alveolar crest in 5 foxhounds. Standardized radiographs were taken at baseline and at monthly intervals until sacrifice at 6 months. Radiographic assessment was carried out by measuring the distance between the top of the implant/abutment and the most coronal bone‐to‐implant contact (DIB), and by evaluation of bone density changes using computer‐assisted densitometric image analysis (CADIA). DIB measurements revealed that in 1‐part, nonsubmerged implants, the most coronal bone‐toimplant contact followed at all time points the rough/smooth implant interface. In all 2‐part implants, nonsubmerged and submerged, the most coronal bone‐to‐implant contact was consistently located approximately 2 mm below the microgap. In addition, CADIA values for all 2‐part implants were decreased in the most coronal area‐ofinterest (AOI). All bone changes were statistically significant and detectable 1 month after implant placement in nonsubmerged implants or 1 month after abutment connection in submerged implants. Neither implant position nor individual dog effects were statistically significant. These results demonstrate that the rough/smooth implant interface as well as the location of the microgap have a significant effect on marginal bone formation as evaluated by standardized longitudinal radiography. Bone remodeling occurs rapidly during the early healing phase after implant placement for nonsubmerged implants and after abutment connection for submerged implants. J Periodontol 1997;68:1117–1130.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1902/jop.1997.68.11.1117

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Metadata

Authors
Hermann, J. S., Cochran, D. L., Nummikoski, P. V., & Buser, D.
Venue
Journal of Periodontology
Publisher
Wiley
Published
1997-11
Volume
68
Issue
11
Pages
1117-1130
ISSN
  • 0022-3492 (ISSN-L)
  • 1943-3670
OpenAlex
W2101360759
Cited by
678
References
28
FWCI
10.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Crestal Bone Changes Around Titanium Implants. A Radiographic Evaluation of Unloaded Nonsubmerged and Submerged Implants in the Canine Mandible. https://app.cochat.ai/papers/10.1902/jop.1997.68.11.1117
The paper
Hermann, J. S., Cochran, D. L., Nummikoski, P. V., & Buser, D. (1997). Crestal Bone Changes Around Titanium Implants. A Radiographic Evaluation of Unloaded Nonsubmerged and Submerged Implants in the Canine Mandible. Journal of Periodontology. https://doi.org/10.1902/jop.1997.68.11.1117

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.