The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An EMG-Controlled Hand Exoskeleton for Natural Pinching
Open accessAbstract
Spinal cord and other local injuries often lead to partial paralysis while the brain stays fully functional. When this partial paralysis occurs in the hand, these individuals are not able to execute daily activities on their own even if their arms are functional. To remedy this problem, a lightweight, low-profile orthotic exoskeleton has been designed to restore dexterity to paralyzed hands. The exoskeleton’s movements are controlled by the user’s available electromyography (EMG) signals. The device has two actuators controlling the index finger flexion that can be used to perform a pinching motion against a fixed thumb. Using this orthotic device, a new control technique was developed to allow for a natural reaching and pinching sequence by utilizing the natural residual muscle activation patterns. To design this controller, two actuator control algorithms were explored with a quadriplegic (C5/C6) subject and it was determined that a simple binary control algorithm allowed for faster interaction with objects over a variable control algorithm. The binary algorithm was then used as an enabling algorithm to activate the exoskeleton movements when the natural sequence of muscle activities found a pattern related to a pinch. This natural pinching technique has shown significant promise toward realistic neural control of wearable robotic devices to assist paralyzed individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Au, A. T. C., & Kirsch, R. F. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895950 · Cited by 182
Cited by
Soft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
An EMG-Based Control for an Upper-Limb Power-Assist Exoskeleton Robot
Kiguchi, K., & Hayashi, Y. (2012) · IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics) · doi:10.1109/tsmcb.2012.2185843 · Cited by 531
Current hand exoskeleton technologies for rehabilitation and assistive engineering
Heo, P., Gu, G. M., Lee, S.-J., Rhee, K., & Kim, J. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0107-2 · Cited by 517
Robot-assisted rehabilitation of hand function
Balasubramanian, S., Klein, J., & Burdet, E. (2010) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32833e99a4 · Cited by 287
Metadata
- Authors
- Lucas, L., Mechanical Engineering, C. M. U., DiCicco, M., Matsuoka, Y., & Robotics Institute, C. M. U.
- Venue
- Journal of Robotics and Mechatronics
- Publisher
- Fuji Technology Press Ltd.
- Published
- 2004-10-20
- Volume
- 16
- Issue
- 5
- Pages
- 482-488
- ISSN
- 0915-3942 (ISSN-L)
- 1883-8049
- OpenAlex
- W61707987
- Cited by
- 194
- References
- 1
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An EMG-Controlled Hand Exoskeleton for Natural Pinching. https://app.cochat.ai/papers/10.20965/jrm.2004.p0482
- The paper
- Lucas, L., Mechanical Engineering, C. M. U., DiCicco, M., Matsuoka, Y., & Robotics Institute, C. M. U. (2004). An EMG-Controlled Hand Exoskeleton for Natural Pinching. Journal of Robotics and Mechatronics. https://doi.org/10.20965/jrm.2004.p0482
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.