The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Development of an Exoskeleton to Support Eating Movements in Patients with Essential Tremor
Open accessAbstract
Essential tremor is a disorder that causes involuntary oscillations in patients both while they are engaged in actions and when maintaining a posture. Such patients face serious difficulties in performing such daily living activities as eating, drinking, and writing. We have been developing an electromyogram-controlled exoskeleton to suppress tremors and support the eating movements of these patients. This exoskeleton is designed to suppress tremors and support voluntary movement at the elbow in terms of flexion and extension: movement of the elbow is essential in eating movements. In this study, we examined the effectiveness of our prototype exoskeleton at suppressing tremors. Our goal was to answer two questions: To what extent are the oscillations suppressed when wearing the exoskeleton? Is the exoskeleton able to suppress the oscillations sufficiently to allow eating movements? We were able to confirm experimentally that our exoskeleton can effectively suppress tremors to support eating movements.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The Fujie exoskeleton reduced tremor by 50-80% compared to not wearing the exoskeleton when intention recognition was simulated with a switch triggered by an essential tremor patient.
“Instead, they tested the tremor suppression simulating this recognition with a switch triggered by an ET patient (56), obtaining that the tremor was reduced by 50–80% compared to not wearing the exoskeleton.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [56]
Citations
Cites
Deuschl, G., Raethjen, J., Lindemann, M., & Krack, P. (2001) · Muscle & Nerve · doi:10.1002/mus.1063 · Cited by 508
Ando, T., Robotics and Design for Innovative Healthcare, G. S. O. M., Watanabe, M., Nishimoto, K., Matsumoto, Y., Seki, M., Fujie, M. G., & Graduate School of Creative Science and Engineering, F. O. S. A. E. (2012) · Journal of Robotics and Mechatronics · doi:10.20965/jrm.2012.p0141 · Cited by 27
Self-citationTremor frequency based filter to extract voluntary movement of patients with essential tremor
Matsumoto, Y., Seki, M., Ando, T., Kobayashi, Y., Iijima, H., Nagaoka, M., & Fujie, M. G. (2012) · 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290905 · Cited by 16
Self-citation
Flagged first, then by citations
Research works printed but not linked: 20
- R. Elble and W. Koller, “Tremor. Baltimore,” MD: Johns Hopkins Univ. Press, 1990.
- E. Rocon, J. Belda-Lois, J. Sanchez-Lancuesta, and J. L. Pons, “Pathological tremor management : Modeling, compensatory technology and evaluation,” Technol. Disability, Vol.16, pp. 13-18, 2004. · DOI · Paper page
- A. P. L. Bo, P. Poignet, D. Zhang, and W. T. Ang, “FES-controlled co-contraction strategies for pathological tremor compensation,” The 2009 IEEE/RSJ IROS, pp. 1633-1638, 2009. · DOI
- A. P. L. Bo and P. Poignet, “Tremor attenuation using FES-based joint stiffness control,” IEEE Int. Conf. on Robotics and Automation, pp. 2928-2933, 2010.
- J. A. Gallego, E. Rocon, and J. L. Pons, “Estimation of instantaneous tremor parameters for FES-based tremor suppression,” IEEE Int. Conf. on Robotics and Automation, pp. 1633-1638, 2010. · DOI
- K. Yano, E. Ohara, S. Horihata, T. Aoki, and Y. Nishimoto, “Development of Tremor Suppression Control System Using Adaptive Filter and Its Application to Meal-assist Robot,” Trans. of the Society of Instrument and Control Engineers, Vol.45, No.12, pp .638-645, 2009. · DOI
- T. Komatsuzaki, Y. Iwata, and K. Ogawa, “A Study on Vibration Control of Physiological Tremor using Dynamic Absorber,” Trans. of the Japan Society of Mechanical Engineering, Part C, Vol74, No.3, pp. 679-685, 2008. · DOI
- Y. Hasegawa, Y. Mikami, K. Watanabe, Z. Firouzimehr, and Y. Sankai, “Wearable handling support system for paralyzed patient,” IEEE/RSJ IROS, pp. 741-746, 2008. · DOI
- K. Kiguchi, Y. Imada, and M. Liyanage, “EMG-Based Neuro-Fuzzy Control of a 4DOF Upper-Limb Power-Assist Exoskelton,” 29th IEEE EMBS, pp. 3040-3043, 2007.
- T. Ando, J. Okamoto, and M. G. Fujie, “Intelligent corset to support rollover of cancer bone metastasis patients,” The 2008 IEEE/RSJ IROS, pp. 723-728, 2008. · DOI
- ED. Louis, K. Marder, L. Cote, D. Wilder, MX. Tang, R. Lantiqua, B. Gurland, and R. Mayeux,“Prevalence of a History of Shaking in Persons 65 years of Age and Older: Diagnostic and Functional Correlates,” Mov. Disord., Vol.11, No.1, pp. 63-69, January 1996. · DOI
- J. Kotovsky and M.J. Rosen, “A wearable tremor-suppression orthosis,” J. of Rehabilitation Research and Development, Vol.35, No.4, October 1998, pp. 373-387.
- M. Rosen, A. Arnold, I. Baiges, M.Aisen, and S. Eglowstein, “A controlled-energy-dissipation orthosis for functional suppression of intention tremors,” J. of Rehabilitation Research and Development, Vol.32, No.1, pp. 1-16, 1995.
- M. Seki, Y. Matsumoto, T. Ando, Y. Kobayashi, H. Iijima, M. Nagaoka, and M. G. Fujie, “Development of Essential Tremor Noise Suppression Filter for Voluntary Movement Extraction from surface EMG,” 2011 IEEE EMBC, 2011.
- M. Seki, Y. Matsumoto, T. Ando, Y. Kobayashi, H. Iijima, M. Nagaoka, and M. G. Fujie, “Development of Robotic Upper Limb Orthosis with Tremor Suppressiblity and Elbow Joint Movability,” 2011 IEEE SMC, 2011 · DOI
- M. Seki, Y. Matsumoto, T. Ando, Y. Kobayashi, H. Iijima, M. Nagaoka, and M. G. Fujie, “The weight load inconsistency effect on voluntary movement recognition of essential tremor patient,” Int. Conf. on Robotics and Biomimetics, 2011. · DOI
- Y. Matsumoto, M. Seki, T. Ando, Y. Kobayashi, H. Iijima, M. Nagaoka, and M. G. Fujie, “Analysis of EMG Signals of Patients with Essential Tremor Focusing on the Change of Tremor Frequency,” Annual Int. Conf. of IEEE Engineering in Medicine and Biology Society, Vol.24 No.27, pp. 2244-2250, August 28 to September 2, 2012. · DOI
- P. D. Faghri, M. M. Rodgers, R. M. Glaser, J. G. Bors, C. Ho, and P. Akuthota, “The effects of functional electrical stimulation on shoulder subluxation arm function recovery, and shoulder pain in hemiplegic stroke patients,” Physical Medicine and Rehabilitation, Vol.75, No.1, pp. 73-79, 1994. · DOI
- J. H. Burridge, P. N. Taylor, S. A. Hagen, D. E. Wood, and I. D. Swain, “The effects of common peroneal stimulation on the effect and speed of walking: a randomized controlled trial with chronic hemiplegic patients,” Clinical Rehabilitation, Vol.11, No.3, pp. 201-210, August 1997. · DOI
- A. I. R. Kottink, L. J. M. Oostendorp, J. H. Buurke, and M. J. IJzerman, “The orthotic effect of functional electrical stimulation on the improvement of walking in stroke patients with a dropped foot: a systematic review,” Artificial Organs, Vol.28, Issue 6, , pp. 577-586, June 2004 · DOI
Cited by
Sorted by citations
A Review on Wearable Technologies for Tremor Suppression
Lora-Millan, J. S., Delgado-Oleas, G., Benito-León, J., & Rocon, E. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.700600 · Cited by 62
“Instead, they tested the tremor suppression simulating this recognition with a switch triggered by an ET patient (56), obtaining that the tremor was reduced by 50–80% compared to not wearing the exoskeleton.”
BackgroundMethodInfluential
Metadata
- Authors
- Matsumoto, Y., Waseda University, 3.-4.-1. O., Seki, M., Ando, T., Kobayashi, Y., Nakashima, Y., Iijima, H., Nagaoka, M., Fujie, M. G., MONOZUKURI Mechatronics Laboratory, K. S. C., Robotics Development Center, C. M. I. D., Rehabilitation Engineering Department, Y. R. C., & Department of Rehabilitation Medicine, G. S.
- Affiliations
- Waseda University (JP)
- Juntendo University (JP)
- Venue
- Journal of Robotics and Mechatronics
- Publisher
- Fuji Technology Press Ltd.
- Published
- 2013-12-20
- Volume
- 25
- Issue
- 6
- Pages
- 949-958
- ISSN
- 0915-3942 (ISSN-L)
- 1883-8049
- OpenAlex
- W2574299146
- Cited by
- 23
- References
- 3
- Citations by year
- 2025: 2 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 7 · 2020: 2 · 2019: 3 · 2018: 1 · 2017: 1 · 2016: 1 · 2014: 3
- FWCI
- 0.74
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- cc-by-nd
- Locations
- Journal of Robotics and Mechatronics (publishedVersion, cc-by-nd)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- essential tremor, exoskeleton, tremor suppression, elbow flexion and extension, activities of daily living, assistive robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review