The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Pathological tremor management: Modelling, compensatory technology and evaluation
Abstract
A great deal of effort has been devoted in the past decades in the generic area of tremor management. Specific topics of modelling for objective classification of pathological tremor out of kinematics and physiological data, compensatory technologies and evaluation rating tools are just a few examp les of application field. This paper introduces a comprehensive review of research work in this generic field during the last decades. In particular special focus has been put on the systems approach and thus a specific section on modelling has been included. Aspects related to experimental protocol and tremor pattern identification are reviewed in detail with the aim of drawing a practical guideline when compensatory technology has to be developed. The current status on ambulatory and non-ambulatory tremor reduction technologies is given in the section devoted to tremor management. Here compensatory technologies are classified according to the tremor isolation and the tremor reduction approaches. Eventually, we finish our discussion with those aspects related to tremor evaluation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“in fact, 65% of patients suffering from upper limb tremor report serious difficulties in performing their activities of daily living [2].”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [2]
In the citing paper
“In particular, it has been clinically demonstrated that increase of damping and/or inertia in the upper limb leads to an effective tremor reduction [2,8].”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [2]
In the citing paper
“Voluntary motions are typically considered to have a frequency spectra below 2 Hz [43, 44]”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [44]
In the citing paper
“One of the basic premises of almost any tremor suppression approach, used also in this work, is that tremor frequencies occupy a different frequency range than most daily voluntary motions (Rocon and Belda-Lois, 2004).”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Rocon and Belda-Lois, 2004
In the citing paper
“The transfer function associated with Figure 4 can be expressed as a second-order system similar to that provided in Pledgie et al. (2000), Rocon and Belda-Lois (2004), and Taheri et al. (2011), with the addition of a differentiator to obtain a velocity output.”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Rocon and Belda-Lois (2004)
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Discrete-Time Signal Processing
Oppenheim, A. V., & Schafer, R. W. (1989) · Cited by 12,572
Deuschl, G., Raethjen, J., Lindemann, M., & Krack, P. (2001) · Muscle & Nerve · doi:10.1002/mus.1063 · Cited by 508
Bain, P. G., Findley, L. J., Atchison, P., Behari, M., Vidailhet, M., Gresty, M., Rothwell, J. C., Thompson, P. D., & Marsden, C. D. (1993) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.56.8.868 · Cited by 437
Lippold, O. C. J. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009018 · Cited by 286
Handbook of Parkinson's Disease
(2013) · CRC Press eBooks · doi:10.1201/b14361 · Cited by 272
Tremor and other oscillations in neuromuscular systems
Stein, R. B., & Oĝuztöreli, M. N. (1976) · Biological Cybernetics · doi:10.1007/bf00365525 · Cited by 264
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 2×
“Riviere [31] computed the uncompensated and compensated error by subtracting the estimated voluntary motion from the uncompensated and compensated, relatively.”
MethodFatigue in patients with Parkinson's disease
Karlsen, K., Larsen, J. O., Tandberg, E., & J�rgensen, K. (1999) · Movement Disorders · doi:10.1002/1531-8257(199903)14:2<288::aid-mds1014>3.0.co;2-m · Cited by 236
Atypical antipsychotics in the treatment of drug-induced psychosis in Parkinson's disease
Friedman, J. H., & Factor, S. A. (2000) · Movement Disorders · doi:10.1002/1531-8257(200003)15:2<309::aid-mds1016>3.0.co;2-p · Cited by 216
The rhythmical activity of groups of motor units in the voluntary contraction of muscle
Lippold, O. C. J., Redfearn, J. W. T., & Vučo, J. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005828 · Cited by 169
Cited by
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
Self-citationReal-Time Estimation of Pathological Tremor Parameters from Gyroscope Data
Gallego, J., Rocon, E., Roa, J. O., Moreno, J., & Pons, J. L. (2010) · Sensors · doi:10.3390/s100302129 · Cited by 107
Self-citationEmpirical Mode Decomposition: a novel technique for the study of tremor time series
de Lima, E. R., Andrade, A. O., Pons, J. L., Kyberd, P., & Nasuto, S. J. (2006) · Medical and Biological Engineering and Computing · doi:10.1007/s11517-006-0065-x · Cited by 93
Self-citationRehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression
Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570451 · Cited by 87
Self-citationA neuroprosthesis for tremor management through the control of muscle co-contraction
Gallego, J. Á., Rocon, E., Belda-Lois, J. M., & Pons, J. L. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-36 · Cited by 81
“According to some estimates, more than 65% of those who suffer from pathological tremor—referred to as tremor in the remainder of the paper—at the upper limb report serious difficulties when performing their activities of daily living (ADLs) [3].”
BackgroundSelf-citation
Metadata
- Authors
- Rocon, E., Belda-Lois, J. M., Sanchez-Lacuesta, J. J., & Pons, J. L.
- Affiliations
- Instituto de Automática Industrial, Madrid, Spain
- ORCID
- Pons, J.L.
- Venue
- Technology and Disability
- Publisher
- SAGE Publications
- Published
- 2004-07-19
- Volume
- 16
- Issue
- 1
- Pages
- 3-18
- ISSN
- 1055-4181 (ISSN-L)
- 1878-643X
- OpenAlex
- W1855262381
- Cited by
- 89
- References
- 40
- Citations by year
- 2025: 3 · 2024: 3 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 3 · 2019: 5 · 2018: 3 · 2017: 7 · 2016: 4 · 2014: 7 · 2013: 9 · 2012: 5
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Technology and Disability (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- pathological tremor, tremor control, tremor classification, experimental protocol
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pathological tremor management: Modelling, compensatory technology and evaluation. https://app.cochat.ai/papers/10.3233/tad-2004-16102
- The paper
- Rocon, E., Belda-Lois, J. M., Sanchez-Lacuesta, J. J., & Pons, J. L. (2004). Pathological tremor management: Modelling, compensatory technology and evaluation. Technology and Disability. https://doi.org/10.3233/tad-2004-16102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.