Automatic evaluation of endometrial receptivity in three-dimensional transvaginal ultrasound images based on 3D U-Net segmentation
Open accessAbstract
Background: Endometrial thickness is an essential factor affecting female fertility. Clinically, ultrasound imaging is the first choice for the examination of uterine and endometrial-related diseases. However, the boundary of some endometrial is challenging to distinguish due to the effects of image resolution and noise. In addition, the irregular shape of the endometrium makes it more difficult for doctors to measure its thickness. Through the automatic segmentation and extraction of the endometrium, the maximum thickness of the endometrium can be measured automatically and accurately. This provides a quantitative index for doctors to use diagnostically. Methods: In this study, 85 cases of three-dimensional transvaginal ultrasound (3D TVUS) images were collected retrospectively, including 75 cases of endometrial adhesion and 10 cases of non-adhesion. Firstly, the ultrasound images were filtered by block-matching and 3D filtering and speckle reducing anisotropic diffusion (SRAD). These two kinds of filtered images were combined with the original image to construct a three-channel image. Then, the augmented images were sent to 3D U-Net to realize endometrium segmentation. The performance of the segmentation models was evaluated using the Dice similarity coefficient (DSC), Jaccard, sensitivity, and 95th percentile Hausdorff distance (HD95). Finally, the medial axis transform was used to extract the endometrial centerline, based on which the endometrial thickness could be automatically measured. Results: The endometrium segmentation method proposed in this paper achieved 90.83% in Dice, 83.35% in Jaccard, 90.85% in sensitivity, and 12.75 mm in HD95 in the testing set. Taking the doctor's manual measurement as the gold standard, 94.20% of the automatic endometrial thickness measurements based on the segmentation results were within the allowable error range of clinical diagnosis. Conclusions: This paper presents an automatic endometrium segmentation and thickness measurement method for 3D TVUS images. The experimental results show that this method has high segmentation accuracy to recognize endometrial adhesion images. Furthermore, the thickness measurement based on the segmentation results has high reliability and repeatability, and the accuracy can meet clinical diagnosis needs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures









Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The only two studies using 3D imaging outlined the superiority of this data to 2D imaging for its improved capability in identifying the endometrial−myometrial junction [205,206].”
From Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology (2023) · cites this paper as [206]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Wang et al. and Zhao et al. conducted their studies based on 3D US images [205,206].”
The cited source says what the claim attributes to it.
In the citing paper
“All but one study investigated the AI performance for the assessment of endometrial thickness, texture, or uterine adhesions [205,206,207,208].”
The cited source says what the claim attributes to it.
In the citing paper
“limited data for algorithm training [205,206]”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists are queued
They are fetched later and appear here then.
References 38 · Cited by 20
Research works printed but not linked: 6
- [2]2. Wolman I, Jaffa AJ, Sagi J, Hartoov J, Amster R, David MP. Transvaginal ultrasonographic measurements of endometrial thickness: a reproducibility study. J Clin Ultrasound 1996;24:351-4.
- [3]3. Yang X, Hong D, Yu L, Ma H, Na L. The application of ultrasound monitoring on follicle and endometrium in infertility treatment. Guangzhou Med J 2013;44:17-20.
- [7]7. Cui YF, Liu Y, Zhang J, Yang XK, Yan-Min MA, Wang SY, Jia CW. The investigation of the correlation between endometrial thickness and pregnancy outcomes in IVF-ET. Chinese Journal of Birth Health & Heredity 2014;22:113-5.
- [13]13. Xing LI, Sang JZ, Bai LJ, Wei-Yang LV, Hui LI, Liang X, Ultrasound DO. Application Value of Comparison Transvaginal Three-Dimensional Energy Doppler Ultrasound and Ultrasound Elastography in the Early Diagnosis of Cervical Cancer. China Medical Devices 2017;32:57-60,82.
- [16]16. Bjoern O, Sevald B, Anders Herman T, Klaus PS, Sturla HE-N. editors. 3D transvaginal ultrasound imaging for identification of endometrial abnormality. Proceedings of the SPIE; 1995.
- [24]24. Singh SP, Wang L, Gupta S, Goli H, Padmanabhan P, Gulyás B. 3D Deep Learning on Medical Images: A Review. Sensors (Basel) 2020;20:5097.
Metadata
- Authors
- Wang, X., Bao, N., Xin, X., Tan, J., Li, H., Zhou, S., & Liu, H.
- Affiliations
- Northeastern University (CN)
- Sheng Jing Hospital (CN)
- Affiliated Hospital of Guizhou Medical University (CN)
- Shenyang Institute of Automation (CN)
- Corresponding author
- Li, Hong
- Liu, Hao
- Venue
- Quantitative Imaging in Medicine and Surgery
- Publisher
- AME Publishing Company
- Published
- 2022-08
- Volume
- 12
- Issue
- 8
- Pages
- 4095-4108
- ISSN
- 2223-4292 (ISSN-L)
- 2223-4306
- PMC
- PMC9338380
- OpenAlex
- W4285553345
- Cited by
- 20
- References
- 38
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 2 · 2023: 4
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Quantitative Imaging in Medicine and Surgery (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- SIA OpenIR (Chinese Academy of Sciences) (submittedVersion)
- Funders
- National Natural Science Foundation of China (61873257)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Medicine › Obstetrics and Gynecology › Gynecological conditions and treatments
- Keywords
- endometrial receptivity, 3D transvaginal ultrasound, 3D U-Net, endometrial adhesions, image denoising, speckle reducing anisotropic diffusion, medial axis transform, endometrial thickness
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic evaluation of endometrial receptivity in three-dimensional transvaginal ultrasound images based on 3D U-Net segmentation. https://app.cochat.ai/papers/10.21037/qims-21-1155
- The paper
- Wang, X., Bao, N., Xin, X., Tan, J., Li, H., Zhou, S., & Liu, H. (2022). Automatic evaluation of endometrial receptivity in three-dimensional transvaginal ultrasound images based on 3D U-Net segmentation. Quantitative Imaging in Medicine and Surgery. https://doi.org/10.21037/qims-21-1155
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.