Automatic evaluation of endometrial receptivity in three-dimensional transvaginal ultrasound images based on 3D U-Net segmentation

Open access
Wang, Xue, Bao, Nan, Xin, Xing, Tan, Jichun, Li, Hong, Zhou, Shi, Liu, Hao · 2022 · Quantitative Imaging in Medicine and Surgery

Abstract

Background: Endometrial thickness is an essential factor affecting female fertility. Clinically, ultrasound imaging is the first choice for the examination of uterine and endometrial-related diseases. However, the boundary of some endometrial is challenging to distinguish due to the effects of image resolution and noise. In addition, the irregular shape of the endometrium makes it more difficult for doctors to measure its thickness. Through the automatic segmentation and extraction of the endometrium, the maximum thickness of the endometrium can be measured automatically and accurately. This provides a quantitative index for doctors to use diagnostically. Methods: In this study, 85 cases of three-dimensional transvaginal ultrasound (3D TVUS) images were collected retrospectively, including 75 cases of endometrial adhesion and 10 cases of non-adhesion. Firstly, the ultrasound images were filtered by block-matching and 3D filtering and speckle reducing anisotropic diffusion (SRAD). These two kinds of filtered images were combined with the original image to construct a three-channel image. Then, the augmented images were sent to 3D U-Net to realize endometrium segmentation. The performance of the segmentation models was evaluated using the Dice similarity coefficient (DSC), Jaccard, sensitivity, and 95th percentile Hausdorff distance (HD95). Finally, the medial axis transform was used to extract the endometrial centerline, based on which the endometrial thickness could be automatically measured. Results: The endometrium segmentation method proposed in this paper achieved 90.83% in Dice, 83.35% in Jaccard, 90.85% in sensitivity, and 12.75 mm in HD95 in the testing set. Taking the doctor's manual measurement as the gold standard, 94.20% of the automatic endometrial thickness measurements based on the segmentation results were within the allowable error range of clinical diagnosis. Conclusions: This paper presents an automatic endometrium segmentation and thickness measurement method for 3D TVUS images. The experimental results show that this method has high segmentation accuracy to recognize endometrial adhesion images. Furthermore, the thickness measurement based on the segmentation results has high reliability and repeatability, and the accuracy can meet clinical diagnosis needs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.21037/qims-21-1155

Cites

Statistics

Figures

Figure 1 Flow chart of data screening process. 3D, three-dimensional.
Figure 1 Flow chart of data screening process. 3D, three-dimensional.CC BY-NC-ND · PubMed Central
Figure 2 Images of the endometrium. The first row shows normal endometrium, the second shows the endometrium with adhesion, and the red line shows the endometrial boundary in each section. (A) Coronal section images; (B) transverse section images; and (C) sagittal section images.
Figure 2 Images of the endometrium. The first row shows normal endometrium, the second shows the endometrium with adhesion, and the red line shows the endometrial boundary in each section. (A) Coronal section images; (B) transverse section images; and (C) sagittal section images.CC BY-NC-ND · PubMed Central
Figure 3 Flowchart of the method. The first red column on the right shows the different sections obtained by 3D U-net segmentation and the reconstructed endometrial images, and the second column shows the segmentation results of the sagittal section used for endometrial thickness measurement. Conv, convolution; BN, batch normalization; Relu, rectified linear units; 3D, three-dimensional; U-net, U-shape network.
Figure 3 Flowchart of the method. The first red column on the right shows the different sections obtained by 3D U-net segmentation and the reconstructed endometrial images, and the second column shows the segmentation results of the sagittal section used for endometrial thickness measurement. Conv, convolution; BN, batch normalization; Relu, rectified linear units; 3D, three-dimensional; U-net, U-shape network.CC BY-NC-ND · PubMed Central
Figure 4 Image filtering. (A) Original image; (B) image filtered by BM3D; and (C) image filtered by SRAD. BM3D, block-matching and 3D filtering; SRAD, speckle reducing anisotropic diffusion.
Figure 4 Image filtering. (A) Original image; (B) image filtered by BM3D; and (C) image filtered by SRAD. BM3D, block-matching and 3D filtering; SRAD, speckle reducing anisotropic diffusion.CC BY-NC-ND · PubMed Central
Figure 5 Automatic endometrium thickness measurement. The orange line is the endometrial border, the yellow line represents the centerline of the endometrium, the blue line represents the maximum thickness of the endometrium, and the green line shows the thickness of the endometrium at different locations. (A) The different sagittal section images; (B) the corresponding endometrium contour and the centerline obtained by MAT; and (C) the corresponding thickness measurements. MAT, medial axis transformation.
Figure 5 Automatic endometrium thickness measurement. The orange line is the endometrial border, the yellow line represents the centerline of the endometrium, the blue line represents the maximum thickness of the endometrium, and the green line shows the thickness of the endometrium at different locations. (A) The different sagittal section images; (B) the corresponding endometrium contour and the centerline obtained by MAT; and (C) the corresponding thickness measurements. MAT, medial axis transformation.CC BY-NC-ND · PubMed Central
Figure 6 Endometrium segmentation results of 2D and 3D U-Net. (A) The original image; (B) the label of the endometrium; and (C,D) show the segmentation results of 2D and 3D U-Net, respectively. 2D, two-dimensional; 3D, three-dimensional; U-net, U-shape network.
Figure 6 Endometrium segmentation results of 2D and 3D U-Net. (A) The original image; (B) the label of the endometrium; and (C,D) show the segmentation results of 2D and 3D U-Net, respectively. 2D, two-dimensional; 3D, three-dimensional; U-net, U-shape network.CC BY-NC-ND · PubMed Central
Figure 7 Endometrium segmentation results of 3D U-Net from the different training datasets. (A) The original images; (B) the labels of the endometrium; (C-E) the segmentation results training from OD, AD, and EAD respectively; and (F,G) the segmentation results training from PD and EPD. 3D U-Net, three-dimensional U-shape network; OD, the origin data; AD, the augmented data; EAD, the enhanced augmented data; PD, the patched data; EPD, the enhanced patched data.
Figure 7 Endometrium segmentation results of 3D U-Net from the different training datasets. (A) The original images; (B) the labels of the endometrium; (C-E) the segmentation results training from OD, AD, and EAD respectively; and (F,G) the segmentation results training from PD and EPD. 3D U-Net, three-dimensional U-shape network; OD, the origin data; AD, the augmented data; EAD, the enhanced augmented data; PD, the patched data; EPD, the enhanced patched data.CC BY-NC-ND · PubMed Central
Figure 8 Endometrium thickness measurement results. The orange line is the endometrial border, the yellow line represents the centerline of the endometrium, and the blue line represents the maximum thickness of the endometrium.
Figure 8 Endometrium thickness measurement results. The orange line is the endometrial border, the yellow line represents the centerline of the endometrium, and the blue line represents the maximum thickness of the endometrium.CC BY-NC-ND · PubMed Central
Figure 9 Coronal section images of poor-quality images.
Figure 9 Coronal section images of poor-quality images.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists are queued

They are fetched later and appear here then.

References 38 · Cited by 20

Research works printed but not linked: 6

  1. [2]2. Wolman I, Jaffa AJ, Sagi J, Hartoov J, Amster R, David MP. Transvaginal ultrasonographic measurements of endometrial thickness: a reproducibility study. J Clin Ultrasound 1996;24:351-4.
  2. [3]3. Yang X, Hong D, Yu L, Ma H, Na L. The application of ultrasound monitoring on follicle and endometrium in infertility treatment. Guangzhou Med J 2013;44:17-20.
  3. [7]7. Cui YF, Liu Y, Zhang J, Yang XK, Yan-Min MA, Wang SY, Jia CW. The investigation of the correlation between endometrial thickness and pregnancy outcomes in IVF-ET. Chinese Journal of Birth Health & Heredity 2014;22:113-5.
  4. [13]13. Xing LI, Sang JZ, Bai LJ, Wei-Yang LV, Hui LI, Liang X, Ultrasound DO. Application Value of Comparison Transvaginal Three-Dimensional Energy Doppler Ultrasound and Ultrasound Elastography in the Early Diagnosis of Cervical Cancer. China Medical Devices 2017;32:57-60,82.
  5. [16]16. Bjoern O, Sevald B, Anders Herman T, Klaus PS, Sturla HE-N. editors. 3D transvaginal ultrasound imaging for identification of endometrial abnormality. Proceedings of the SPIE; 1995.
  6. [24]24. Singh SP, Wang L, Gupta S, Goli H, Padmanabhan P, Gulyás B. 3D Deep Learning on Medical Images: A Review. Sensors (Basel) 2020;20:5097.

Metadata

Authors
Wang, X., Bao, N., Xin, X., Tan, J., Li, H., Zhou, S., & Liu, H.
Affiliations
  • Northeastern University (CN)
  • Sheng Jing Hospital (CN)
  • Affiliated Hospital of Guizhou Medical University (CN)
  • Shenyang Institute of Automation (CN)
Corresponding author
  • Li, Hong
  • Liu, Hao
Venue
Quantitative Imaging in Medicine and Surgery
Published
2022-08
Volume
12
Issue
8
Pages
4095-4108
ISSN
  • 2223-4292 (ISSN-L)
  • 2223-4306
OpenAlex
W4285553345
Cited by
20
References
38
Citations by year
2026: 4 · 2025: 10 · 2024: 2 · 2023: 4
FWCI
1.31
Type
journal article
Language
en
Open access
Licence
cc-by-nc-nd
Locations
  • Quantitative Imaging in Medicine and Surgery (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • SIA OpenIR (Chinese Academy of Sciences) (submittedVersion)
Funders
National Natural Science Foundation of China (61873257)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Obstetrics and Gynecology › Gynecological conditions and treatments
Keywords
endometrial receptivity, 3D transvaginal ultrasound, 3D U-Net, endometrial adhesions, image denoising, speckle reducing anisotropic diffusion, medial axis transform, endometrial thickness

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic evaluation of endometrial receptivity in three-dimensional transvaginal ultrasound images based on 3D U-Net segmentation. https://app.cochat.ai/papers/10.21037/qims-21-1155
The paper
Wang, X., Bao, N., Xin, X., Tan, J., Li, H., Zhou, S., & Liu, H. (2022). Automatic evaluation of endometrial receptivity in three-dimensional transvaginal ultrasound images based on 3D U-Net segmentation. Quantitative Imaging in Medicine and Surgery. https://doi.org/10.21037/qims-21-1155

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.