A computer-based record and clinical monitoring system for ambulatory care.
Open accessThe DOI matches its Crossref record.
Abstract
The Regenstrief Medical Record system is a computer-based medical record system for ambulatory care which has been in operation since 1973. For each patient served, it contains a core medical record including most objective data (treatment records, lab, x-ray and EKG, etc.) and selected items of subjective data. Its supports the care of patients by presenting the clinical data in clear and compact reports and by reminding the physician about clinical conditions that need corrective action. The generation of these computer reminders is totally controlled by physician authored protocols. Each protocol defines an important clinical condition and the content of the reminder to be triggered when that condition occurs. Physician compliance to the standards implicit in these protocols is improved by this feedback. Patient data are captured by computerized ancillary services, (laboratory and outpatient pharmacy) and by manual techniques. Much of these data are recorded by hand (as marks or numbers) on computer-tailored forms which can be optically read by machine. This system represents a different approach to the difficult problems of efficiently using and maintaining patient records.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electronic Health Records: Then, Now, and in the Future
Evans, R. S. (2016) · Yearbook of Medical Informatics · doi:10.15265/iys-2016-s006 · Cited by 768
Physicians' Decisions to Override Computerized Drug Alerts in Primary Care
Weingart, S. N., Toth, M., Sands, D. Z., Aronson, M. D., Davis, R. B., & Phillips, R. S. (2003) · Archives of Internal Medicine · doi:10.1001/archinte.163.21.2625 · Cited by 487
Clinical Decision Support: a 25 Year Retrospective and a 25 Year Vision
Sittig, D. F., Wright, A., & Middleton, B. (2016) · Yearbook of Medical Informatics · doi:10.15265/iys-2016-s034 · Cited by 277
Computerized Display of Past Test Results: Effect on Outpatient Testing
TIERNEY, W. M., McDONALD, C. J., MARTIN, D. K., HUI, S. L., & ROGERS, M. P. (1987) · Annals of Internal Medicine · doi:10.7326/0003-4819-107-4-569 · Cited by 204
Self-citationThe Application of Computer-Based Medical-Record Systems in Ambulatory Practice
Barnett, G. O. (1984) · New England Journal of Medicine · doi:10.1056/nejm198406213102506 · Cited by 177
Metadata
- Authors
- McDonald, C. J., Murray, R., Jeris, D., Bhargava, B., Seeger, J., & Blevins, L.
- Venue
- American Journal of Public Health
- Publisher
- American Public Health Association
- Published
- 1977-03
- Volume
- 67
- Issue
- 3
- Pages
- 240-245
- ISSN
- 0090-0036 (ISSN-L)
- 1541-0048
- OpenAlex
- W2074769586
- Cited by
- 88
- References
- 0
- FWCI
- 14.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A computer-based record and clinical monitoring system for ambulatory care. https://app.cochat.ai/papers/10.2105/ajph.67.3.240
- The paper
- McDonald, C. J., Murray, R., Jeris, D., Bhargava, B., Seeger, J., & Blevins, L. (1977). A computer-based record and clinical monitoring system for ambulatory care. American Journal of Public Health. https://doi.org/10.2105/ajph.67.3.240
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.