The carpal tunnel syndrome. A study of carpal canal pressures.
The DOI matches its Crossref record.
Abstract
We measured intracarpal canal pressures with the wick catheter in fifteen patients with carpal tunnel syndrome and in twelve control subjects. The mean pressure in the carpal canal was elevated significantly in the patients. When the wrist was in neutral position, the mean pressure was thirty-two millimeters of mercury. With 90 degrees of wrist flexion the pressure increased to ninety-four millimeters of mercury, while with 90 degrees of wrist extension the mean pressure was 110 millimeters of mercury. The pressure in the control subjects with the wrist in neutral position was 2.5 millimeters of mercury; with wrist flexion the pressure rose to thirty-one millimeters of mercury, and with wrist extension it increased to thirty millimeters of mercury. Carpal tunnel release brought about an immediate and sustained reduction in pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
AAEM Quality Assurance Committee, Jablecki, C. K., Andary, C. M. T., So, Y. T., Wilkins, D. E., & Williams, F. H. (1993) · Muscle & Nerve · doi:10.1002/mus.880161220 · Cited by 707
Assistive devices for balance and mobility: Benefits, demands, and adverse consequences
Bateni, H., & Maki, B. E. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.04.023 · Cited by 687
Coppieters, M. W., & Butler, D. S. (2008) · Manual Therapy · doi:10.1016/j.math.2006.12.008 · Cited by 385
Pathophysiology of Nerve Compression Syndromes: Response of Peripheral Nerves to Loading*
REMPEL, D., DAHLIN, L., & LUNDBORG, G. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199911000-00013 · Cited by 378
Self-citationWork-Related Cumulative Trauma Disorders of the Upper Extremity
Rempel, D. M. (1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03480060084035 · Cited by 371
Topp, K. S., & Boyd, B. S. (2006) · Physical Therapy · doi:10.1093/ptj/86.1.92 · Cited by 361
Lundborg, G., Gelberman, R. H., Minteer-Convery, M., Lee, Y. F., & Hargens, A. R. (1982) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(82)80175-5 · Cited by 352
Self-citation(2005) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.2005.11753844 · Cited by 340
Lundborg, G., Myers, R., & Powell, H. (1983) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.46.12.1119 · Cited by 316
Self-citationDoes This Patient Have Carpal Tunnel Syndrome?
D'Arcy, C. A. (2000) · JAMA · doi:10.1001/jama.283.23.3110 · Cited by 300
Complications of arteriovenous hemodialysis access: Recognition and management
Padberg, F. T., Calligaro, K. D., & Sidawy, A. N. (2008) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2008.08.067 · Cited by 270
Impact of occupations and job tasks on the prevalence of carpal tunnel syndrome.
Hagberg, M., Morgenstern, H., & Kelsh, M. (1992) · Scandinavian Journal of Work, Environment & Health · doi:10.5271/sjweh.1564 · Cited by 260
Ultrasound treatment for treating the carpal tunnel syndrome: randomised "sham" controlled trial
Ebenbichler, G. R., Resch, K. L., Nicolakis, P., Wiesinger, G. F., Uhl, F., Ghanem, A.-H., & Fialka, V. (1998) · BMJ · doi:10.1136/bmj.316.7133.731 · Cited by 241
Effects of smartphone overuse on hand function, pinch strength, and the median nerve
İNal, E. E., Demİrcİ, K., Çetİntürk, A., Akgönül, M., & Savaş, S. (2015) · Muscle & Nerve · doi:10.1002/mus.24695 · Cited by 230
Nerve and tendon gliding exercises and the conservative management of carpal tunnel syndrome
Rozmaryn, L. M., Dovelle, S., Rothman, E. R., Gorman, K., Olvey, K. M., & Bartko, J. J. (1998) · Journal of Hand Therapy · doi:10.1016/s0894-1130(98)80035-5 · Cited by 214
Stress carpal tunnel pressures in patients with carpal tunnel syndrome and normal patients
Szabo, R. M., & Chidgey, L. K. (1989) · The Journal of Hand Surgery · doi:10.1016/0363-5023(89)90178-0 · Cited by 209
Shacklock, M. (1995) · Physiotherapy · doi:10.1016/s0031-9406(05)67024-1 · Cited by 202
ANATOMY, FUNCTION, AND PATHOPHYSIOLOGY OF PERIPHERAL NERVES AND NERVE COMPRESSION
Lundborg, G., & Dahlin, L. B. (1996) · Hand Clinics · doi:10.1016/s0749-0712(21)00303-6 · Cited by 201
Self-citationTreatment of Carpal Tunnel Syndrome with Nerve and Tendon Gliding Exercises
Akalin, E., El, Ö., Peker, Ö., Şenocak, Ö., Tamci, Ş., Gülbahar, S., Çakmur, R., & Öncel, S. (2002) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-200202000-00006 · Cited by 200
Eitivipart, A. C., Viriyarojanakul, S., & Redhead, L. (2018) · Hong Kong Physiotherapy Journal · doi:10.1142/s1013702518300010 · Cited by 198
Weiss, N. D., Gordon, L., Bloom, T., So, Y., & Rempel, D. M. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199511000-00008 · Cited by 189
Effects of computer mouse design and task on carpal tunnel pressure
Keir, P. J., Bach, J. M., & Rempel, D. (1999) · Ergonomics · doi:10.1080/001401399184992 · Cited by 187
A handy review of carpal tunnel syndrome: From anatomy to diagnosis and treatment
Ghasemi-rad, M. (2014) · World Journal of Radiology · doi:10.4329/wjr.v6.i6.284 · Cited by 179
Excursion and Strain of the Median Nerve*
WRIGHT, T. W., GLOWCZEWSKIE, F., WHEELER, D., MILLER, G., & COWIN, D. (1996) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199612000-00013 · Cited by 175
Entrapment neuropathies: pathophysiology and pathogenesis
Rempel, D. M., & Diao, E. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2003.09.009 · Cited by 171
“(n1⁄4 15, 12) [6], 2.”
Schmid, A. B., Fundaun, J., & Tampin, B. (2020) · PAIN Reports · doi:10.1097/pr9.0000000000000829 · Cited by 168
“These pressures are often reached in patients with entrapment neuropathies.(31,60,132,139) The ensuing reversal of the pressure gradient necessary to assure adequate blood supply could”
BackgroundChronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode
Tyler, D. J., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569263 · Cited by 144
Relationships and Mechanisms Between Occupational Risk Factors and Distal Upper Extremity Disorders
Keir, P. J., Farias Zuniga, A., Mulla, D. M., & Somasundram, K. G. (2021) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720819860683 · Cited by 57
The design of and chronic tissue response to a composite nerve electrode with patterned stiffness
Freeberg, M. J., Stone, M. A., Triolo, R. J., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6632 · Cited by 54
Metadata
- Authors
- Gelberman, R. H., Hergenroeder, P. T., Hargens, A. R., Lundborg, G. N., & Akeson, W. H.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1981-03
- Volume
- 63
- Issue
- 3
- Pages
- 380-383
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2114999298
- Cited by
- 744
- References
- 0
- FWCI
- 6.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.