The DOI matches its Crossref record.
Infection rates after 3175 total hip and total knee replacements performed with and without a horizontal unidirectional filtered air-flow system.
Abstract
To determine the effect of the ventilation system on infection rates after total hip and total knee arthroplasties performed in operating rooms with and without a horizontal unidirectional filtered air-flow system, using modern antiseptic conditions and antibiotic prophylaxis, all of the single-stage procedures (3175 of a total of 4769) were subjected to statistical analysis and fifty-seven matched pairs for controls were established. A reduced infection rate after total hip replacement (from 1.4 to 0.9 per cent) and an increased infection rate after total knee replacement (from 1.4 to 3.9 per cent) were found when patients operated on in the filtered laminar air-flow operating room were compared with those whose operations were done in two conventional rooms. This pattern was statistically significant and was believed to be due to the positions of the operating team and of the wound with respect to the air flow. Prospectively accumulated factors (such as the experience of the surgeon, the duration of surgery, the diagnosis, and the patient's age) as well as retrospectively accumulated factors (such as predisposing conditions of the patient) did not explain the observed patterns of infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Phillips, J. E., Crane, T. P., Noy, M., Elliott, T. S. J., & Grimer, R. J. (2006) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.88b7.17150 · Cited by 513
Bongartz, T., Halligan, C. S., Osmon, D. R., Reinalda, M. S., Bamlet, W. R., Crowson, C. S., Hanssen, A. D., & Matteson, E. L. (2008) · Arthritis Care & Research · doi:10.1002/art.24060 · Cited by 388
Release of gentamicin from acrylic bone cement
Bunetel, L., Segui, A., Cormier, M., Percheron, E., & Langlais, F. (1989) · Clinical Pharmacokinetics · doi:10.2165/00003088-198917040-00006 · Cited by 123
Gosden, P. E., MacGowan, A. P., & Bannister, G. C. (1998) · Journal of Hospital Infection · doi:10.1016/s0195-6701(98)90255-9 · Cited by 118
Metadata
- Authors
- Salvati, E. A., Robinson, R. P., Zeno, S. M., Koslin, B. L., Brause, B. D., & Wilson, P. D.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1982-04
- Volume
- 64
- Issue
- 4
- Pages
- 525-535
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1864582390
- Cited by
- 290
- References
- 0
- FWCI
- 7.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Infection rates after 3175 total hip and total knee replacements performed with and without a horizontal unidirectional filtered air-flow system. https://app.cochat.ai/papers/10.2106/00004623-198264040-00007
- The paper
- Salvati, E. A., Robinson, R. P., Zeno, S. M., Koslin, B. L., Brause, B. D., & Wilson, P. D. (1982). Infection rates after 3175 total hip and total knee replacements performed with and without a horizontal unidirectional filtered air-flow system. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-198264040-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.