The DOI matches its Crossref record.
A roentgenographic, biomechanical, and histological evaluation of vascularized and non-vascularized segmental fibular canine autografts.
Abstract
Advocates of vascularized bone grafts believe that these grafts should have a decreased time to graft-host union, and that they should be mechanically stronger than conventional (non-vascularized) grafts. The objectives of the present study were to determine the rate and pattern of repair in vascularized autogenous cortical bone grafts, to determine the mechanical strength of the grafts, and to correlate the mechanical strength with the biological repair. Forty-nine adult male mongrel dogs were divided into six groups to evaluate conventional (non-vascularized), cuff (periosteal-encased, non-vascularized), and vascularized segmental grafts. The fibula was the site of experimentation and all grafts were four-centimeter cortical segments. The vascularized and conventional grafts were analyzed at two, six, twelve, and twenty-four weeks. The cuff grafts were analyzed at twenty-four weeks and were compared with conventional grafts to assess the effect of the periosteal soft tissue. Roentgenograms were made every two weeks to evaluate the time to union. The mechanical strength of each graft was assessed by determining rapid torsional load to failure. Biological repair was assessed by tetracycline labeling for new-bone formation and by microradiographic techniques for porosity and cross-sectional areas. The study showed that conventional and cuff grafts were similar in terms of mechanical and biological repair at six months. At all sampling intervals, the vascularized grafts exhibited histological findings that were consistent with viability. The conventional and vascularized grafts underwent different mechanisms of repair. The conventional, non-vascularized grafts healed by peripheral and internal resorption followed by callus encasement and osteonal remodeling.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advancing biomaterials of human origin for tissue engineering
Chen, F.-M., & Liu, X. (2016) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2015.02.004 · Cited by 1,158
BONE-GRAFTING AND BONE-GRAFT SUBSTITUTES
FINKEMEIER, C. G. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200203000-00020 · Cited by 1,099
Bone Graft Materials: An Overview of the Basic Science
Bauer, T. W., & Muschler, G. F. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200002000-00003 · Cited by 998
Baldwin, P., Li, D. J., Auston, D. A., Mir, H. S., Yoon, R. S., & Koval, K. J. (2019) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0000000000001420 · Cited by 773
Autogenous Bone Graft: Donor Sites and Techniques
Myeroff, C., & Archdeacon, M. (2011) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.01513 · Cited by 637
Metadata
- Authors
- Dell, P. C., Burchardt, H., & Glowczewskie, F. P.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1985-01
- Volume
- 67
- Issue
- 1
- Pages
- 105-112
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2120117457
- Cited by
- 166
- References
- 0
- FWCI
- 1.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A roentgenographic, biomechanical, and histological evaluation of vascularized and non-vascularized segmental fibular canine autografts. https://app.cochat.ai/papers/10.2106/00004623-198567010-00013
- The paper
- Dell, P. C., Burchardt, H., & Glowczewskie, F. P. (1985). A roentgenographic, biomechanical, and histological evaluation of vascularized and non-vascularized segmental fibular canine autografts. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-198567010-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.