The DOI matches its Crossref record.
Prediction of vertebral body compressive fracture using quantitative computed tomography.
Abstract
We performed quantitative computed tomography in vitro on the first and third lumbar vertebrae in human cadavera using a dibasic potassium phosphate phantom for calibration. The quantitative computed-tomography numbers exhibited a significant positive correlation (R2 = 0.89, p less than 0.0001) with direct measurements of the apparent density of the vertebral trabecular bone. We also conducted uniaxial compression tests to failure of the vertebral bodies after removal of the posterior elements, and found that vertebral compressive strength was also correlated at a high level of significance (R2 = 0.82, p less than 0.0001) with direct measurement of the trabecular apparent density. These findings suggested the possibility that the quantitative computed-tomography values might be directly predictive of vertebral compressive strength. However, when we correlated the quantitative computed-tomography values directly with vertebral compressive strength, the results (R2 = 0.46, p less than 0.061) were suggestive but not quite significant. All vertebral bodies failed by compression of the end-plate, suggesting only a modest structural role for the cortical shell under these loading conditions. This was confirmed by comparing the compressive load to failure of twenty additional pairs of vertebrae that were tested with and without an intact vertebral cortex. Removal of the cortex was associated with approximately 10 per cent reduction in vertebral load to failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401
Biomechanical considerations of animal models used in tissue engineering of bone
Liebschner, M. A. K. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00515-5 · Cited by 329
Determinants of the mechanical properties of bones
Martin, R. B. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90379-2 · Cited by 316
Mosekilde, L., & Mosekilde, L. (1990) · Bone · doi:10.1016/8756-3282(90)90052-z · Cited by 272
Metadata
- Authors
- McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1985-10
- Volume
- 67
- Issue
- 8
- Pages
- 1206-1214
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2117135793
- Cited by
- 432
- References
- 0
- FWCI
- 12.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prediction of vertebral body compressive fracture using quantitative computed tomography. https://app.cochat.ai/papers/10.2106/00004623-198567080-00010
- The paper
- McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985). Prediction of vertebral body compressive fracture using quantitative computed tomography. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-198567080-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.