The DOI matches its Crossref record.
Intramedullary nailing of femoral shaft fractures. Part II: Fracture-healing with static interlocking fixation.
Abstract
A consecutive, prospective series of ninety-seven patients who had 100 fractures of the femoral shaft that were treated with static interlocking nailing was analyzed to determine the incidence of union of the fracture without planned conversion from static to dynamic intramedullary fixation as a technique to stimulate healing of the fracture. Eighty-four patients (eighty-seven fractures) were studied through union of the fracture (average follow-up, fourteen months). Eighty-five (98 per cent) of the eighty-seven fractures healed with static interlocking fixation. Two patients needed conversion from static to dynamic interlocking fixation because of inadequate fracture-healing; both progressed to uneventful union. The time to full weight-bearing (average, eleven weeks) was individualized for each patient and depended on the cortical contact of the major fragments, the presence of bridging callus as seen on radiographs, and the extent of other injuries of the ipsilateral lower extremity. No deformation or failure of the static interlocking device developed after early walking with weight-bearing, but fatigue failure of one nail occurred in a non-ambulatory patient who had an intracranial injury. Pain related to soft-tissue irritation by the prominent heads of the interlocking screws, clinically presenting as bursitis or snapping of the iliotibial band, was severe enough in six patients to necessitate removal of either the proximal or the distal screw after union of the fracture. We concluded that static interlocking of intramedullary nails in femoral shaft fractures does not appreciably inhibit the process of healing of the fracture, and that routine conversion to dynamic intramedullary fixation, although occasionally necessary, need not be performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Retrograde Versus Antegrade Nailing of Femoral Shaft Fractures
Ricci, W. M., Bellabarba, C., Evanoff, B., Herscovici, D., DiPasquale, T., & Sanders, R. (2001) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200103000-00003 · Cited by 280
Glatt, V., Evans, C. H., & Tetsworth, K. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2016.00678 · Cited by 194
Claes, L., Blakytny, R., Besse, J., Bausewein, C., Ignatius, A., & Willie, B. (2011) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e3181e3d994 · Cited by 75
Ru, J.-Y., Chen, L.-X., Hu, F.-Y., Shi, D., Xu, R., Du, J.-W., & Niu, Y.-F. (2018) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-018-0886-y · Cited by 16
Metadata
- Authors
- Brumback, R. J., Uwagie-Ero, S., Lakatos, R. P., Poka, A., Bathon, G. H., & Burgess, A. R.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1988-12
- Volume
- 70
- Issue
- 10
- Pages
- 1453-1462
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W4301044224
- Cited by
- 228
- References
- 0
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intramedullary nailing of femoral shaft fractures. Part II: Fracture-healing with static interlocking fixation. https://app.cochat.ai/papers/10.2106/00004623-198870100-00003
- The paper
- Brumback, R. J., Uwagie-Ero, S., Lakatos, R. P., Poka, A., Bathon, G. H., & Burgess, A. R. (1988). Intramedullary nailing of femoral shaft fractures. Part II: Fracture-healing with static interlocking fixation. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-198870100-00003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.