Position of the wrist associated with the lowest carpal-tunnel pressure: implications for splint design.
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Increased carpal-tunnel pressure has been implicated in the pathophysiology of carpal tunnel syndrome, but it is not known whether splints that immobilize the wrist in a functional position of extension minimize carpal tunnel pressure. To determine the position of the wrist that results in the lowest carpal-tunnel pressure, twenty control subjects and four patients who had carpal tunnel syndrome were evaluated with use of a new, dynamic method that continuously measures carpal tunnel pressure throughout the range of motion of the wrist. The pressure was measured by means of a pressure transducer connected to a flexible catheter that had been inserted into the carpal canal. The position of the wrist was measured simultaneously with use of a two-axis electrogoniometer. Aided by a computer monitor that displayed a moving line of real-time carpal-tunnel pressure, each subject was instructed to move the wrist throughout the range of motion and to adjust it to the position that corresponded to the lowest carpal-tunnel pressure. For the control subjects, the lowest carpal-tunnel pressure averaged 8 +/- 4 millimeters of mercury (1.07 +/- 0.53 kilopascals), and the average position of the wrist associated with the lowest pressure was 2 +/- 9 degrees of extension and 2 +/- 6 degrees of ulnar deviation.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PHALEN, G. S. (1966) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196648020-00001 · Cited by 1,169
The carpal tunnel syndrome. A study of carpal canal pressures.
Gelberman, R. H., Hergenroeder, P. T., Hargens, A. R., Lundborg, G. N., & Akeson, W. H. (1981) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198163030-00009 · Cited by 744
Effects of graded compression on intraneural blood flow
Rydevik, B., Lundborg, G., & Bagge, U. (1981) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(81)80003-2 · Cited by 465
Lundborg, G., Gelberman, R. H., Minteer-Convery, M., Lee, Y. F., & Hargens, A. R. (1982) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(82)80175-5 · Cited by 352
The nerve lesion in the carpal tunnel syndrome.
Sunderland, S. (1976) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.39.7.615 · Cited by 302
Carpal-tunnel syndrome. Results of a prospective trial of steroid injection and splinting.
Gelberman, R. H., Aronson, D., & Weisman, M. H. (1980) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198062070-00020 · Cited by 295
Stress carpal tunnel pressures in patients with carpal tunnel syndrome and normal patients
Szabo, R. M., & Chidgey, L. K. (1989) · The Journal of Hand Surgery · doi:10.1016/0363-5023(89)90178-0 · Cited by 209
Okutsu, I., Ninomiya, S., Hamanaka, I., Kuroshima, N., & Inanami, H. (1989) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198971050-00006 · Cited by 193
Evaluation of thermography in the diagnosis of selected entrapment neuropathies
So, Y. T., Olney, R. K., & Aminoff, M. J. (1989) · Neurology · doi:10.1212/wnl.39.1.1 · Cited by 171
Self-citationNavarro, V. (1974) · The Lancet · doi:10.1016/s0140-6736(74)91996-5 · Cited by 156
Carpal Tunnel Syndrome: A Scientific Basis for Clinical Care
Gelherman, R. H., Rydevik, B. L., Pess, G. M., Szabo, R. M., & Lundborg, G. (1988) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(20)30335-7 · Cited by 155
Predictive Factors in the Non-Surgical Treatment of Carpal Tunnel Syndrome
KAPLAN, S., Glickel, S. Z., & EATON, R. (1990) · Journal of Hand Surgery (European Volume) · doi:10.1016/0266-7681(90)90061-8 · Cited by 140
Pressure and Nerve Lesion in the Carpal Tunnel
Werner, C.-O., Elmqvist, D., & Ohlin, P. (1983) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678308996576 · Cited by 131
The intrinsic vascularization of human peripheral nerves: Structural and functional aspects
Lundborg, G. (1979) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(79)80102-1 · Cited by 121
The Acute Carpal Tunnel Syndrome
Bauman, T. D., Gelberman, R. H., Mubarak, S. J., & Garfin, S. R. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198105000-00019 · Cited by 119
Rojviroj, S., Sirichativapee, W., Kowsuwon, W., Wongwiwattananon, J., Tamnanthong, N., & Jeeravipoolvarn, P. (1990) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.72b3.2187880 · Cited by 115
Luchetti, R., Schönhuber, R., Cicco, G. D., Alfarano, M., Deluca, S., & Landi, A. (1989) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678909149305 · Cited by 90
Cited by
Pathophysiology of Nerve Compression Syndromes: Response of Peripheral Nerves to Loading*
REMPEL, D., DAHLIN, L., & LUNDBORG, G. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199911000-00013 · Cited by 378
Self-citationTreatment of Carpal Tunnel Syndrome with Nerve and Tendon Gliding Exercises
Akalin, E., El, Ö., Peker, Ö., Şenocak, Ö., Tamci, Ş., Gülbahar, S., Çakmur, R., & Öncel, S. (2002) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-200202000-00006 · Cited by 200
“The finding that flexion and extension of the wrist increases carpal tunnel pressure and the implication of increased carpal tunnel pressure in the pathophysiology of CTS suggest that immobilization in a splint benefits the patients by preventing the elevation of carpal tunnel pressure.(9,10) Many authors have suggest…”
BackgroundEffects of computer mouse design and task on carpal tunnel pressure
Keir, P. J., Bach, J. M., & Rempel, D. (1999) · Ergonomics · doi:10.1080/001401399184992 · Cited by 187
Self-citationMUGGLETON, J. M., ALLEN, R., & CHAPPELL, P. H. (1999) · Ergonomics · doi:10.1080/001401399185405 · Cited by 180
The validity of upper-limb neurodynamic tests for detecting peripheral neuropathic pain.
Nee, R. J., Jull, G. A., Vicenzino, B., & Coppieters, M. W. (2012) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2012.3988 · Cited by 171
Metadata
- Authors
- Weiss, N. D., Gordon, L., Bloom, T., So, Y., & Rempel, D. M.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1995-11
- Volume
- 77
- Issue
- 11
- Pages
- 1695-1699
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1802269748
- Cited by
- 189
- References
- 17
- FWCI
- 4.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.