Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 358

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

The Effect of Gap Formation at the Repair Site on the Strength and Excursion of Intrasynovial Flexor Tendons. AN EXPERIMENTAL STUDY ON THE EARLY STAGES OF TENDON-HEALING IN DOGS*

GELBERMAN, RICHARD H., BOYER, MARTIN I., BRODT, MICHAEL D., WINTERS, STEVEN C., SILVA, MATTHEW J.·1999·The Journal of Bone & Joint Surgery

Abstract

BACKGROUND: Elongation (gap formation) at the repair site has been associated with the formation of adhesions and a poor functional outcome after repair of flexor tendons. Our objectives were to evaluate the prevalence of gap formation in a clinically relevant canine model and to assess the effect of gap size on the range of motion of the digits and the mechanical properties of the tendons. METHODS: We performed operative repairs after sharp transection of sixty-four flexor tendons in thirty-two adult dogs. Rehabilitation with passive motion was performed daily until the dogs were killed at ten, twenty-one, or forty-two days postoperatively. Eight tendons ruptured in vivo. In the fifty-six intact specimens, the change in the angles of the proximal and distal interphalangeal joints and the linear excursion of the flexor tendon were measured as a 1.5-newton force was applied to the tendon. The gap at the repair site was then measured, and the isolated tendons were tested to failure in tension. RESULTS: Twenty-nine tendons had a gap of less than one millimeter, twelve had a gap of one to three millimeters, and fifteen had a gap of more than three millimeters. Neither the time after the repair nor the size of the gap was found to have a significant effect on motion parameters (p > 0.05); however, the ultimate force, repair-site rigidity, and repair-site strain at twenty newtons were significantly affected by these parameters (p < 0.05). Testing of the tendons with a gap of three millimeters or less revealed that, compared with the ten-day specimens, the forty-two-day specimens failed at a significantly (90 percent) higher force (p < 0.01) and had a significantly (320 percent) increased rigidity (p < 0.01) and a significantly (60 percent) decreased strain at twenty newtons (p < 0.05). In contrast, the tensile properties of the tendons that had a gap of more than three millimeters did not change significantly with time. CONCLUSIONS: Our data indicate that, in a dog model involving sharp transection followed by repair, a gap at the repair site of more than three millimeters does not increase the prevalence of adhesions or impair the range of motion but does prevent the accrual of strength and stiffness that normally occurs with time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-199907000-00010

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 358

Metadata

Authors
GELBERMAN, R. H., BOYER, M. I., BRODT, M. D., WINTERS, S. C., & SILVA, M. J.
Venue
The Journal of Bone & Joint Surgery
Published
1999-07
Volume
81
Issue
7
Pages
975-82
ISSN
0021-9355 (ISSN-L)
OpenAlex
W2292542132
Cited by
358
References
10
FWCI
7.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Effect of Gap Formation at the Repair Site on the Strength and Excursion of Intrasynovial Flexor Tendons. AN EXPERIMENTAL STUDY ON THE EARLY STAGES OF TENDON-HEALING IN DOGS*. https://app.cochat.ai/papers/10.2106/00004623-199907000-00010
The paper
GELBERMAN, R. H., BOYER, M. I., BRODT, M. D., WINTERS, S. C., & SILVA, M. J. (1999). The Effect of Gap Formation at the Repair Site on the Strength and Excursion of Intrasynovial Flexor Tendons. AN EXPERIMENTAL STUDY ON THE EARLY STAGES OF TENDON-HEALING IN DOGS*. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199907000-00010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.