Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 542

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Complications Associated with Pedicle Screws*

LONSTEIN, JOHN E., DENIS, FRANCIS, PERRA, JOSEPH H., PINTO, MANUEL R., SMITH, MICHAEL D., WINTER, ROBERT B. · 1999 · The Journal of Bone & Joint Surgery

Abstract

BACKGROUND: The safety and the effectiveness of pedicle-screw instrumentation in the spine have been questioned despite its use worldwide to enhance stabilization of the spine. This review was performed to answer questions about the technique of insertion and the nature and etiology of complications directly attributable to the screws. METHODS: We performed a retrospective review of all of the pedicle-screw procedures that were done by us from January 1, 1984, to December 31, 1993. We inserted 4790 screws during 915 operative procedures on 875 patients; 668 (76.3 percent) of the patients had a lumbosacral arthrodesis. The mean duration of follow-up was three years (range, two to five years). The accuracy of screw placement was assessed on intraoperative, immediate postoperative, and follow-up radiographs with use of a technique that was developed by one of us (F. D.); this technique has yet to be validated to determine the prevalence of various types of error. RESULTS: Of the 4790 screws, 4548 (94.9 percent) had been inserted within the pedicle and the vertebral body. One hundred and thirty-four (2.8 percent) of the screws had perforated the anterior cortex, and this was the most common type of perforation. One hundred and fifteen (2.4 percent) of the screws were associated with complications that could be ascribed to the use of pedicle screws. The most common problem was late-onset discomfort or pain related to a pseudarthrosis or perhaps to the screws; this problem was associated with 1102 (23.0 percent) of the screws, used in 222 (24.3 percent) of the procedures. The symptoms necessitated removal of the instrumentation with or without repair of the pseudarthrosis. A pseudarthrosis was found during forty-six (20.7 percent) of the 222 procedures. Irritation of a nerve root occurred after nine procedures (1.0 percent) and was caused by eleven screws (0.2 percent); it was more commonly caused by medially placed screws. Three patients had residual neurological weakness despite removal of the screws. Twenty-five screws (0.5 percent), used in twenty procedures (2.2 percent), broke. The screws that broke were of an early design. A pseudarthrosis was found in thirteen of twenty patients who had broken screws. Sixteen of the twenty patients had an exploration; three of them were found to have a solid fusion, and thirteen were found to have a pseudarthrosis. The remaining four patients had evidence of a solid fusion on radiographs and had no pain. CONCLUSIONS: There are few problems associated with the insertion of screws, provided that the surgeon is experienced and adheres to the principles and details of the operative technique. Our review revealed a low rate of postoperative complications related to pedicle screws. The problem of late-onset pain may be related to the implants or to the stiffness of the construct; however, it is difficult to accurately identify its exact etiology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-199911000-00003

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 542

Metadata

Authors
LONSTEIN, J. E., DENIS, F., PERRA, J. H., PINTO, M. R., SMITH, M. D., & WINTER, R. B.
Venue
The Journal of Bone & Joint Surgery
Published
1999-11
Volume
81
Issue
11
Pages
1519-28
ISSN
0021-9355 (ISSN-L)
OpenAlex
W1899693549
Cited by
542
References
4
FWCI
8.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Complications Associated with Pedicle Screws*. https://app.cochat.ai/papers/10.2106/00004623-199911000-00003
The paper
LONSTEIN, J. E., DENIS, F., PERRA, J. H., PINTO, M. R., SMITH, M. D., & WINTER, R. B. (1999). Complications Associated with Pedicle Screws*. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199911000-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.