The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Alumina-on-Alumina Total Hip Arthroplasty: A Minimum 18.5-Year Follow-up Study
Abstract
Background: The purpose of this retrospective study was to report the results, after a minimum of 18.5 years of follow-up, in a consecutive series of total hip arthroplasties performed with an alumina-on-alumina combination. Methods: One hundred and eighteen consecutive total hip arthroplasties were performed in 106 patients between 1979 and 1980. The prostheses combined a 32-mm alumina head and an all-alumina socket. Both components were cemented in eighty-five hips, both components were implanted without cement in twenty-nine, and only the stem was cemented in four. The mean age of the patients at the time of the index arthroplasty was 62.2 years (range, thirty-two to eighty-nine years). Results: At the 18.5 to 20.5-year follow-up evaluation, forty-five patients (fifty-one hips) were alive and had not had a revision, twenty-five patients (twenty-five hips) had undergone revision of one or both components, twenty-seven patients (thirty hips) had died, and nine patients (twelve hips) had been lost to follow-up. The mean Merle d’Aubigné hip score (and standard deviation) was 16.2 ± 1.8 points at the latest follow-up evaluation. The rate of survival at twenty years, with revision for any reason as the end-point, was 85.6% for the cementless cups compared with 61.2% for the cemented cups and 84.9% for the cementless stems compared with 87.3% for the cemented stems. Wear of the prosthetic components was undetectable on plain radiographs. Periprosthetic cystic or scalloped lesions requiring the use of allograft bone during revision were present in three of the twenty-five revised hips. In addition, seven hips had moderate acetabular osteolysis treated with a 4-mm-larger cup. No fracture of the alumina socket or head was recorded. The mean acetabular wear rate in this series was <0.025 mm/yr. Conclusion: With the alumina-on-alumina total hip arthroplasty, minimal wear rates and limited osteolysis can be expected up to twenty years after the operation, provided that sound acetabular component fixation is obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of femoral head size on wear of the polyethylene acetabular component.
Livermore, J., Ilstrup, D., & Morrey, B. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072040-00008 · Cited by 1,024
Goldring, S. R., Schiller, A. L., Roelke, M., Rourke, C. M., OʼNeil, D. A., & Harris, W. H. (1983) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198365050-00001 · Cited by 849
Schulte, K. R., Callaghan, J. J., Kelley, S. S., & Johnston, R. C. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199307000-00002 · Cited by 510
Jiranek, W. A., Machado, M., Jasty, M., Jevsevar, D., Wolfe, H. J., Goldring, S. R., Goldberg, M. J., & Harris, W. H. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199306000-00007 · Cited by 436
Endosteal erosion in association with stable uncemented femoral components.
Maloney, W. J., Jasty, M., Harris, W. H., Galante, J. O., & Callaghan, J. J. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072070-00011 · Cited by 369
Osteolysis in Association with a Total Hip Arthroplasty with Ceramic Bearing Surfaces*
YOON, T. R., ROWE, S. M., JUNG, S. T., SEON, K. J., & MALONEY, W. J. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199810000-00007 · Cited by 169
Loosening and Osteolysis of Cemented Joint Arthroplasties: A Biologic Spectrum
Goodman, S. B., Huie, P., Song, Y., Lee, K., Doshi, A., Rushdieh, B., Woolson, S. T., Maloney, W. J., Schurman, D. J., & Sibley, R. K. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199704000-00017 · Cited by 81
Bioactivity of sol-gel bioactive glass coated alumina implants
Hamadouche, M., Meunier, A., Greenspan, D. C., Blanchat, C., Zhong, J. P., Torre, G. P. L., & Sedel, L. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200011)52:2<422::aid-jbm24>3.0.co;2-p · Cited by 61
Self-citation
Cited by
The role of macrophages in osteolysis of total joint replacement
Ingham, E., & Fisher, J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.035 · Cited by 667
The Biology of Aseptic Osteolysis
Holt, G., Murnaghan, C., Reilly, J., & Meek, R. M. D. (2007) · Clinical Orthopaedics & Related Research · doi:10.1097/blo.0b013e31804b4147 · Cited by 319
Orthopedic applications of silicon nitride ceramics
Bal, B. S., & Rahaman, M. N. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.031 · Cited by 314
Metadata
- Authors
- Hamadouche, M., Boutin, P., Daussange, J., Bolander, M. E., & Sedel, L.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2002-01
- Volume
- 84
- Issue
- 1
- Pages
- 69-77
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W4297634068
- Cited by
- 368
- References
- 8
- FWCI
- 14.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Alumina-on-Alumina Total Hip Arthroplasty: A Minimum 18.5-Year Follow-up Study. https://app.cochat.ai/papers/10.2106/00004623-200201000-00011
- The paper
- Hamadouche, M., Boutin, P., Daussange, J., Bolander, M. E., & Sedel, L. (2002). Alumina-on-Alumina Total Hip Arthroplasty: A Minimum 18.5-Year Follow-up Study. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/00004623-200201000-00011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.