Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Osteolysis in Association with a Total Hip Arthroplasty with Ceramic Bearing Surfaces*

YOON, TAEK RIM, ROWE, SUNG MAN, JUNG, SUNG TAEK, SEON, KWANG JIN, MALONEY, WILLIAM J.·1998·The Journal of Bone & Joint Surgery

Abstract

The results of 103 total hip arthroplasties performed with insertion of a ceramic femoral head and acetabular component in ninety-six patients were reviewed to determine the radiographic prevalence of osteolysis. After a mean duration of follow-up of ninety-two months (range, sixty to 125 months), femoral osteolysis was observed in twenty-three hips (22 per cent), in one of two distinct patterns: linear osteolysis (twelve hips) or scalloping expansile-type osteolysis (eleven hips). The most common locations of osteolysis in the femur were in zones I and VII as described by Gruen et al. Serial radiographs demonstrated that the extent of the osteolysis progressed over time. Osteolysis of the pelvis, noted in forty-nine hips, was always associated with migration of the acetabular socket. No focal osteolysis was observed in association with the stable sockets. Ten patients (ten hips) had a revision because of loosening and migration of the acetabular component. In three of these patients, the femoral stem also was revised. Gross examination revealed evidence of wear of the ceramic bearing surface in all ten patients. Scanning electron microscopy showed cracking and wear marks on the weight-bearing surface. Histological evaluation of the tissue in the periprosthetic membrane demonstrated abundant ceramic wear particles. The interface membrane was composed of a vascularized fibrous connective tissue with macrophages. Ultrastructurally, the macrophages contained numerous phagosomes of various sizes, with electron-dense material within the cytoplasm of the cell. The mean size of the ceramic particles, as determined with scanning electron microscopy, was 0.71 micrometer (range, 0.13 to 7.20 micrometers). This study supports the concept that ceramic wear particles can stimulate a foreign-body response and periprosthetic osteolysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-199810000-00007

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 169

Metadata

Authors
YOON, T. R., ROWE, S. M., JUNG, S. T., SEON, K. J., & MALONEY, W. J.
Venue
The Journal of Bone & Joint Surgery
Published
1998-10
Volume
80
Issue
10
Pages
1459-67
ISSN
0021-9355 (ISSN-L)
OpenAlex
W203987728
Cited by
169
References
1
FWCI
6.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Osteolysis in Association with a Total Hip Arthroplasty with Ceramic Bearing Surfaces*. https://app.cochat.ai/papers/10.2106/00004623-199810000-00007
The paper
YOON, T. R., ROWE, S. M., JUNG, S. T., SEON, K. J., & MALONEY, W. J. (1998). Osteolysis in Association with a Total Hip Arthroplasty with Ceramic Bearing Surfaces*. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199810000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.