Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 296

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Closed Suction Drainage for Hip and Knee Arthroplasty: A Meta-Analysis

Parker, Martyn J., Roberts, Chris P., Hay, Douglas·2004·The Journal of Bone and Joint Surgery-American Volume

Abstract

BACKGROUND: The use of closed-suction drainage systems after total joint replacement is a common practice. The theoretical advantages for the use of drains is a reduction in the occurrence of wound hematomas and infection. The aim of this meta-analysis was to determine, on the basis of the evidence from randomized controlled trials, the advantages and adverse effects of surgical drains. METHODS: All randomized trials, as far as we know, that compared patients managed with closed-suction drainage systems and those managed without a drain following elective hip and knee arthroplasty were considered. The trials were identified with use of searches of the Cochrane Collaboration with no restriction on languages or source. Two authors independently extracted the data, and the methods of all identified trials were assessed. RESULTS: Eighteen studies involving 3495 patients with 3689 wounds were included in the analysis. The pooled results indicated that there was no significant difference between the wounds treated with a drain and those treated without a drain with respect to the occurrence of wound infection (relative risk, 0.73; 95% confidence interval, 0.47 to 1.14), wound hematoma (relative risk, 1.73; 95% confidence interval, 0.74 to 4.07), or reoperations for wound complications (relative risk, 0.52; 95% confidence interval, 0.13 to 1.99). A drained wound was associated with a significantly greater need for transfusion (relative risk, 1.43; 95% confidence interval, 1.19 to 1.72). Reinforcement of wound dressings was required more frequently in the group managed without drains. No difference between the groups was seen with respect to limb-swelling, venous thrombosis, or hospital stay. CONCLUSIONS: Studies to date have indicated that closed suction drainage increases the transfusion requirements after elective hip and knee arthroplasty and has no major benefits. Further randomized trials with use of larger numbers of patients with full reporting of outcomes are indicated before the absence of any benefit, particularly for the outcome of wound infection, can be proved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-200406000-00005

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 296

Metadata

Authors
Parker, M. J., Roberts, C. P., & Hay, D.
Venue
The Journal of Bone and Joint Surgery-American Volume
Published
2004-06
Volume
86
Issue
6
Pages
1146-1152
ISSN
0021-9355 (ISSN-L)
OpenAlex
W2275432868
Cited by
296
References
4
FWCI
9.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Closed Suction Drainage for Hip and Knee Arthroplasty: A Meta-Analysis. https://app.cochat.ai/papers/10.2106/00004623-200406000-00005
The paper
Parker, M. J., Roberts, C. P., & Hay, D. (2004). Closed Suction Drainage for Hip and Knee Arthroplasty: A Meta-Analysis. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/00004623-200406000-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.