CoChat

Safety of Osseointegrated Implants for Transfemoral Amputees: A Two-Center Prospective Cohort Study

Al Muderis, Munjed, Khemka, Aditya, Lord, Sarah J., Van de Meent, Henk, Frölke, Jan Paul M. · 2016 · Journal of Bone and Joint Surgery
Cited by 185

The DOI matches its Crossref record.

Abstract

BACKGROUND: Osseointegrated implants are an alternative for prosthetic attachment for individuals unable to wear a socket following an amputation. The concept of an integrated metal implant communicating with the external environment raises substantial concern about the risk of ascending infection. We report on the safety of press-fit osseointegrated implants currently used in Australia and the Netherlands. METHODS: We prospectively recorded all adverse events in all patients with transfemoral amputation who were managed with an osseointegration implant system between 2009 and 2013 at two centers. The procedure was performed in two stages. A customized porous-coated implant was placed in the first stage, and a stoma was created in the second. Adverse events were categorized according to type (infection or "other") and severity. Infections were classified according to four grades of severity based on clinical and radiographic findings: (1) low-grade soft-tissue infection, (2) high-grade soft-tissue infection, (3) bone infection, and (4) septic implant failure. RESULTS: Eighty-six patients (ninety-one implants), twenty-five to eighty-one years of age, were included in the study and followed for a median of thirty-four months (range, twenty-four to seventy-one months). Thirty-one patients had an uneventful course with no complications; twenty-nine developed infection (all grade 1 or 2); and twenty-six did not develop infection but had one or more other complications requiring intervention, including stoma hypergranulation (seventeen patients), soft-tissue redundancy (fourteen), proximal femoral fracture (three), inadequate osseointegration leading to implant replacement (one), implant breakage (two), and breakage of the pin used as a fail-safe mechanism (twenty-five). CONCLUSIONS: Mild infection and irritation of the soft tissue in the skin-penetration area are common in transfemoral amputees who have an osseointegrated implant. These complications were successfully managed with simple measures. Severe infections resulting in septic implant loosening are rare. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/jbjs.15.00808

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 18

  1. Hagberg, 2001, Consequences of non-vascular trans-femoral amputation: a survey of quality of life, prosthetic use and problems, Prosthet Orthot Int., 25, 186, 10.1080/03093640108726601 · DOI · Paper page
  2. Lyon, 2000, Skin disorders in amputees, J Am Acad Dermatol., 42, 501, 10.1016/S0190-9622(00)90227-5 · doi:10.1016/s0190-9622(00)90227-5
  3. Dillingham, 2001, Use and satisfaction with prosthetic devices among persons with trauma-related amputations: a long-term outcome study, Am J Phys Med Rehabil., 80, 563, 10.1097/00002060-200108000-00003 · DOI · Paper page
  4. Nebergall, 2012, Stable fixation of an osseointegated implant system for above-the-knee amputees: titel RSA and radiographic evaluation of migration and bone remodeling in 55 cases, Acta Orthop., 83, 121, 10.3109/17453674.2012.678799 · doi:10.3109/17453674.2012.678799
  5. Brånemark, 2014, A novel osseointegrated percutaneous prosthetic system for the treatment of patients with transfemoral amputation: A prospective study of 51 patients, Bone Joint J., 96-B, 106, 10.1302/0301-620X.96B1.31905 · DOI · Paper page
  6. Hagberg, 2014, Outcome of percutaneous osseointegrated prostheses for patients with unilateral transfemoral amputation at two-year follow-up, Arch Phys Med Rehabil., 95, 2120, 10.1016/j.apmr.2014.07.009 · DOI
  7. Hagberg, 2008, Osseointegrated trans-femoral amputation prostheses: prospective results of general and condition-specific quality of life in 18 patients at 2-year follow-up, Prosthet Orthot Int., 32, 29, 10.1080/03093640701553922 · DOI · Paper page
  8. Lundberg, 2011, My prosthesis as a part of me: a qualitative analysis of living with an osseointegrated prosthetic limb, Prosthet Orthot Int., 35, 207, 10.1177/0309364611409795 · DOI · Paper page
  9. Tranberg, 2011, Improvements in hip- and pelvic motion for patients with osseointegrated trans-femoral prostheses, Gait Posture., 33, 165, 10.1016/j.gaitpost.2010.11.004 · DOI
  10. Hagberg, 2005, Socket versus bone-anchored trans-femoral prostheses: hip range of motion and sitting comfort, Prosthet Orthot Int., 29, 153, 10.1080/03093640500238014 · DOI · Paper page
  11. Häggström, 2013, Vibrotactile evaluation: osseointegrated versus socket-suspended transfemoral prostheses, J Rehabil Res Dev., 50, 1423, 10.1682/JRRD.2012.08.0135 · DOI
  12. Frossard, 2010, Functional outcome of transfemoral amputees fitted with an osseointegrated fixation: temporal gait characteristics, JPO Journal of Prosthetics and Orthotics., 22, 11, 10.1097/JPO.0b013e3181ccc53d · DOI
  13. Van de Meent, 2013, Walking ability and quality of life in subjects with transfemoral amputation: a comparison of osseointegration with socket prostheses, Arch Phys Med Rehabil., 94, 2174, 10.1016/j.apmr.2013.05.020 · DOI
  14. Tabanella, 2009, Clinical and microbiological determinants of ailing dental implants, Clin Implant Dent Relat Res., 11, 24, 10.1111/j.1708-8208.2008.00088.x · DOI
  15. Tillander, 2010, Osseointegrated titanium implants for limb prostheses attachments: infectious complications, Clin Orthop Relat Res., 468, 2781, 10.1007/s11999-010-1370-0 · DOI · Paper page
  16. Kapadia, 2013, Infection prevention methodologies for lower extremity total joint arthroplasty, Expert Rev Med Devices., 10, 215, 10.1586/erd.12.76 · DOI
  17. Toms, 2006, The management of peri-prosthetic infection in total joint arthroplasty, J Bone Joint Surg Br., 88, 149, 10.1302/0301-620X.88B2.17058 · DOI · Paper page
  18. Engh, 1987, Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results, J Bone Joint Surg Br., 69, 45, 10.1302/0301-620X.69B1.3818732 · doi:10.1302/0301-620x.69b1.3818732

Cited by

See all 185

Metadata

Authors
Al Muderis, M., Khemka, A., Lord, S. J., Van de Meent, H., & Frölke, J. P. M.
Venue
Journal of Bone and Joint Surgery
Published
2016-06-01
Volume
98
Issue
11
Pages
900-909
ISSN
  • 0021-9355 (ISSN-L)
  • 1535-1386
OpenAlex
W2411564508
Cited by
185
References
0
FWCI
8.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Safety of Osseointegrated Implants for Transfemoral Amputees: A Two-Center Prospective Cohort Study. https://app.cochat.ai/papers/10.2106/jbjs.15.00808
The paper
Al Muderis, M., Khemka, A., Lord, S. J., Van de Meent, H., & Frölke, J. P. M. (2016). Safety of Osseointegrated Implants for Transfemoral Amputees: A Two-Center Prospective Cohort Study. Journal of Bone and Joint Surgery. https://doi.org/10.2106/jbjs.15.00808

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.