Plate Versus Tension-Band Wire Fixation for Olecranon Fractures: A Prospective Randomized Trial
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: The aim of this single-center, single-blinded, prospective randomized trial was to compare the outcomes of tension-band wire (TBW) and plate fixation for simple isolated, displaced fractures of the olecranon. Methods: We performed a prospective randomized trial involving 67 patients who were ≥16 to <75 years of age and had an acute isolated, displaced fracture of the olecranon. Patients were randomized to either TBW (n = 34) or plate fixation (n = 33) and were evaluated at 6 weeks, 3 months, 6 months, and 1 year following surgery. The primary outcome measure was the Disabilities of the Arm, Shoulder and Hand (DASH) score at 1 year. Results: The baseline demographic and fracture characteristics of the 2 groups were comparable, except for age, which was lower in the TBW group. The 1-year follow-up rate was 85% (n = 57), with 84% (n = 56) completing the DASH. There was a significant improvement in the DASH score over the 1-year period following surgery (p < 0.001). At 1 year, the DASH score for the TBW group (12.8) did not differ significantly from that of the plate group (8.5) (p = 0.315). The groups also did not differ significantly in terms of range of motion, the Broberg and Morrey score, the Mayo Elbow Score, or the DASH at all assessment points over the 1 year (all p ≥ 0.05). Complication rates were significantly higher in the TBW group (63% compared with 38%; p = 0.042), predominantly because of a significantly higher rate of metalwork removal in symptomatic patients (50.0% compared with 22%; p = 0.021). Four infections occurred, all in the plate group (0% versus 13%; p = 0.114), as did 3 revision surgeries (0% versus 9.4%; p = 0.238). Conclusions: Among active patients with a simple isolated, displaced fracture of the olecranon, no difference was found between TBW and plate fixation in the patient-reported outcome at 1 year following surgery. The complication rate was higher following TBW fixation and was due to a higher rate of implant removal in symptomatic patients. However, the more serious complications of infection and the need for revision surgery occurred exclusively following plate fixation in this trial. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hudak, P. L., Amadio, P. C., Bombardier, C., Beaton, D., Cole, D., Davis, A., Hawker, G., Katz, J. N., Makela, M., Marx, R. G., et al. (1996) · American Journal of Industrial Medicine · doi:10.1002/(sici)1097-0274(199606)29:6<602::aid-ajim4>3.0.co;2-l · Cited by 5,025
Hunsaker, F. G., Cioffi, D. A., Amadio, P. C., Wright, J. G., & Caughlin, B. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200202000-00007 · Cited by 684
Metadata
- Authors
- Duckworth, A. D., Clement, N. D., White, T. O., Court-Brown, C. M., & McQueen, M. M.
- Venue
- Journal of Bone and Joint Surgery
- Published
- 2017-08-02
- Volume
- 99
- Issue
- 15
- Pages
- 1261-1273
- ISSN
- 0021-9355 (ISSN-L)
- 1535-1386
- OpenAlex
- W2742659212
- Cited by
- 164
- References
- 2
- FWCI
- 9.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plate Versus Tension-Band Wire Fixation for Olecranon Fractures: A Prospective Randomized Trial. https://app.cochat.ai/papers/10.2106/jbjs.16.00773
- The paper
- Duckworth, A. D., Clement, N. D., White, T. O., Court-Brown, C. M., & McQueen, M. M. (2017). Plate Versus Tension-Band Wire Fixation for Olecranon Fractures: A Prospective Randomized Trial. Journal of Bone and Joint Surgery. https://doi.org/10.2106/jbjs.16.00773
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.