CoChat

Artificial Intelligence Distinguishes Surgical Training Levels in a Virtual Reality Spinal Task

Open access
Bissonnette, Vincent, Mirchi, Nykan, Ledwos, Nicole, Alsidieri, Ghusn, Winkler-Schwartz, Alexander, Del Maestro, Rolando F., on behalf of the Neurosurgical Simulation & Artificial Intelligence Learning Centre · 2019 · Journal of Bone and Joint Surgery
Cited by 151

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: With the emergence of competency-based training, the current evaluation scheme of surgical skills is evolving to include newer methods of assessment and training. Artificial intelligence through machine learning algorithms can utilize extensive data sets to analyze operator performance. This study aimed to address 3 questions: (1) Can artificial intelligence uncover novel metrics of surgical performance? (2) Can support vector machine algorithms be trained to differentiate “senior” and “junior” participants who are executing a virtual reality hemilaminectomy? (3) Can other algorithms achieve a good classification performance? Methods: Participants from 4 Canadian universities were divided into 2 groups according to their training level (senior and junior) and were asked to perform a virtual reality hemilaminectomy. The position, angle, and force application of the simulated burr and suction instruments, along with tissue volumes that were removed, were recorded at 20-ms intervals. Raw data were manipulated to create metrics to train machine learning algorithms. Five algorithms, including a support vector machine, were trained to predict whether the task was performed by a senior or junior participant. The accuracy of each algorithm was assessed through leave-one-out cross-validation. Results: Forty-one individuals were enrolled (22 senior and 19 junior participants). Twelve metrics related to safety of the procedure, efficiency, motion of the tools, and coordination were selected. Following cross-validation, the support vector machine achieved a 97.6% accuracy. The other algorithms achieved accuracy of 92.7%, 87.8%, 70.7%, and 65.9%, respectively. Conclusions: Artificial intelligence defined novel metrics of surgical performance and outlined training levels in a virtual reality spinal simulation procedure. Clinical Relevance: The significance of these results lies in the potential of artificial intelligence to complement current educational paradigms and better prepare residents for surgical procedures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/jbjs.18.01197

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 151

Metadata

Authors
Bissonnette, V., Mirchi, N., Ledwos, N., Alsidieri, G., Winkler-Schwartz, A., Del Maestro, R. F., & on behalf of the Neurosurgical Simulation & Artificial Intelligence Learning Centre
Venue
Journal of Bone and Joint Surgery
Published
2019-09-20
Volume
101
Issue
23
Pages
e127
ISSN
  • 0021-9355 (ISSN-L)
  • 1535-1386
OpenAlex
W2974089311
Cited by
151
References
1
FWCI
15.34
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial Intelligence Distinguishes Surgical Training Levels in a Virtual Reality Spinal Task. https://app.cochat.ai/papers/10.2106/jbjs.18.01197
The paper
Bissonnette, V., Mirchi, N., Ledwos, N., Alsidieri, G., Winkler-Schwartz, A., Del Maestro, R. F., & on behalf of the Neurosurgical Simulation & Artificial Intelligence Learning Centre. (2019). Artificial Intelligence Distinguishes Surgical Training Levels in a Virtual Reality Spinal Task. Journal of Bone and Joint Surgery. https://doi.org/10.2106/jbjs.18.01197

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.