The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Maintenance of Hardware After Early Postoperative Infection Following Fracture Internal Fixation
Abstract
BACKGROUND: The development of a deep wound infection in the presence of hardware after open reduction and internal fixation presents a clinical dilemma, and there is scant literature to aid in decision-making. The purpose of the present study was to determine the prevalence of osseous union with maintenance of hardware after the development of postoperative infection within six weeks after internal fixation of a fracture. METHODS: The present study included 121 patients from three level-I trauma centers, retrospectively identified from billing and trauma registries, in whom 123 postoperative wound infections with positive intraoperative cultures had developed within six weeks after internal fixation of acute fractures. The incidence of fracture union without hardware removal was calculated, and the parameters that predicted success or failure were evaluated. RESULTS: Eighty-six patients (eighty-seven fractures; 71%) had fracture union with operative débridement, retention of hardware, and culture-specific antibiotic treatment and suppression. Predictors of treatment failure were open fracture (p = 0.03) and the presence of an intramedullary nail (p = 0.01). Several variables were not significant but trended toward an association with failure, including smoking, infection with Pseudomonas species, and involvement of the femur, tibia, ankle, or foot. CONCLUSIONS: Deep infection after internal fixation of a fracture can be treated successfully with operative débridement, antibiotic suppression, and retention of hardware until fracture union occurs. These results may be improved by patient selection based on certain risk factors and the specific bacteria and implants involved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of the fracture healing cascade
Phillips, A. M. (2005) · Injury · doi:10.1016/j.injury.2005.07.027 · Cited by 311
Cited by
Masters, E. A., Trombetta, R. P., de Mesy Bentley, K. L., Boyce, B. F., Gill, A. L., Gill, S. R., Nishitani, K., Ishikawa, M., Morita, Y., Ito, H., et al. (2019) · Bone Research · doi:10.1038/s41413-019-0061-z · Cited by 575
Infection after fracture fixation: Current surgical and microbiological concepts
Metsemakers, W. J., Kuehl, R., Moriarty, T. F., Richards, R. G., Verhofstad, M. H. J., Borens, O., Kates, S., & Morgenstern, M. (2018) · Injury · doi:10.1016/j.injury.2016.09.019 · Cited by 544
Clinical presentation and treatment of orthopaedic implant‐associated infection
Zimmerli, W. (2014) · Journal of Internal Medicine · doi:10.1111/joim.12233 · Cited by 481
On behalf of the Fracture-Related Infection (FRI) group, Metsemakers, W.-J., Morgenstern, M., Senneville, E., Borens, O., Govaert, G. A. M., Onsea, J., Depypere, M., Richards, R. G., Trampuz, A., et al. (2020) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-019-03287-4 · Cited by 313
Self-citationBiodegradable bone implants as a new hope to reduce device-associated infections-a systematic review
Paiva, J. C. C., Oliveira, L., Vaz, M. F., & Costa-de-Oliveira, S. (2022) · Bioengineering · doi:10.3390/bioengineering9080409 · Cited by 53
Metadata
- Authors
- Berkes, M., Obremskey, W. T., Scannell, B., Ellington, J. K., Hymes, R. A., & Bosse, M.
- Venue
- The Journal of Bone and Joint Surgery-American Volume
- Published
- 2010-04
- Volume
- 92
- Issue
- 4
- Pages
- 823-828
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2130275355
- Cited by
- 223
- References
- 1
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Maintenance of Hardware After Early Postoperative Infection Following Fracture Internal Fixation. https://app.cochat.ai/papers/10.2106/jbjs.i.00470
- The paper
- Berkes, M., Obremskey, W. T., Scannell, B., Ellington, J. K., Hymes, R. A., & Bosse, M. (2010). Maintenance of Hardware After Early Postoperative Infection Following Fracture Internal Fixation. The Journal of Bone and Joint Surgery-American Volume. https://doi.org/10.2106/jbjs.i.00470
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.